The AEMC OX 7104-C is a 4-channel digital oscilloscope delivering 1 GHz bandwidth and up to 2.5 GS/s sampling rate for high-frequency signal capture and analysis. Built around a 12-bit vertical resolution architecture with 100,000-point maximum record length, this instrument combines precision measurement with practical field deployment capabilities. The 10.4-inch color LCD touchscreen and intuitive graphical interface enable rapid signal troubleshooting across electronics, power delivery, embedded systems, and manufacturing environments.
Technical Specifications
Oscilloscope Core
• Bandwidth: 1 GHz
• Channels: 4
• Sampling Rate: 2.5 GS/s per channel (2-channel interleaved), 1.25 GS/s per channel (4-channel simultaneous)
• Vertical Resolution: 12 bits
• Record Length: 100,000 points per channel maximum
• Input Impedance: 1 MΩ ± 1% || 15 pF ± 2 pF
• Input Coupling: DC, AC, GND
• Vertical Sensitivity: 500 µV/div to 100 V/div
• Vertical Accuracy: ± 1% of full scale
• Offset Accuracy: ± 0.5% of full scale
• Bandwidth Limit Filters: 20 MHz, 100 MHz, 1 GHz
Triggering and Acquisition
• Trigger Types: Edge, Pulse Width, Video, Pattern, Logic, Rise/Fall Time, Sequence, Timeout, Runt
• Trigger Modes: Auto, Normal, Single, Remote
• Trigger Jitter: < 100 ps RMS
• Trigger Delay: Up to 10 million divisions
• Acquisition Modes: Sample, Average, Peak Detect, High Resolution
Analysis and Display
• Automatic Measurements: Amplitude, Frequency, Period, Pulse Width, Rise Time, Fall Time, Duty Cycle, Overshoot, Preshoot, Mean, RMS, Peak-to-Peak, Positive/Negative Pulse Counts
• Cursor Measurements: Voltage, Time, differential voltage and time
• Math Functions: Add, Subtract, Multiply, Divide, FFT (up to 100,000 points), user-defined equations
• Advanced Modes: Mask Testing, Trend Plot, Histogram, Logic Analyzer (with logic probes)
• Display: 10.4-inch color LCD touchscreen, 800 × 600 SVGA resolution
– Key Features
• Data logging capability for time-series measurement trends
• Dual-input interface design supporting both touchscreen and traditional button navigation
• Peak Detect and High Resolution acquisition modes for transient capture and waveform detail
• Extended trigger delay enables precise timing analysis of complex signal sequences
– Typical Applications
High-frequency component characterization, power supply regulation testing, embedded system debugging, signal integrity analysis, protocol validation, transient event capture, educational laboratory work.
– Compatibility & Integration
• USB Host ports for external storage and printer connectivity
• USB Device port for PC control and data transfer
• Ethernet (RJ-45) for network-based remote operation and file management