The Asset Intertech RIC-1000 ScanWorks Remote Instrumentation Controller is a networked boundary scan controller that bridges ScanWorks software on a host PC with remote units under test via Ethernet. The device distributes test intelligence through the ScanWorks Embedded Instrumentation Engine (EIE) architecture, executing pre-stored tests from onboard memory to streamline validation, debugging, and in-system programming operations. It enables remote access and control over standard TCP/IP connectivity, making it suitable for distributed test environments and field operations.
## Technical Specifications
**Boundary Scan Interface**
• Single Test Access Port (TAP) conforming to IEEE 1149.1 (JTAG)
• Maximum TCK frequency: 50 MHz, selectable in 36 increments from 160 kHz to 50 MHz
• PAUSE-DR state support for devices requiring hold states during shift operations
**Discrete I/O (DIO)**
• Eight bidirectional non-boundary scan DIO signals
• DIO0 supports Write Enable (WE) function for flash programming
• DIO1 monitors Ready/BUSY signals
• Included UUT cable supports four DIO signals; custom cable required for remaining four
**Logic Level Support**
• UUT interface voltages: 1.2 V, 1.5 V, 1.8 V, 2.5 V, and 3.3 V
• Software-configurable via ScanWorks hardware configuration
**Networking**
• Auto-sensing 10/100/1000 Mbps Ethernet (CAT5E/6)
• TCP/IP protocol
• Initial IP assignment via USB flash drive text file; reconfigurable via telnet
• Factory-assigned permanent MAC address
**Power**
• Supplied with 5 V, 4 A AC-DC power supply
## Key Features
• Distributed test architecture reduces computational load on host PC
• EMI-resistant rugged enclosure design
• Software-controlled TAP and DIO voltage levels
• Efficient remote test execution from onboard memory
## Typical Applications
• Remote boundary scan and JTAG testing
• In-system flash programming and firmware updates
• Board-level validation and debug operations
• Multi-site test environments over Ethernet infrastructure
## Compatibility & Integration
The RIC-1000 integrates with the Asset Intertech ScanWorks platform, requiring ScanWorks host software for operation and configuration.
**Included Accessories**
• One 2 ft RIC-1000 UUT cable
• One 2 m CAT5E Ethernet cable
• One 5 V 4 A AC-DC power supply