The Boonton 4200-6E is a single-channel RF power meter designed for accurate and reliable power measurements. It features a dynamic range, a high sampling rate, and compatibility with a wide range of Boonton power sensors. Ideal for various applications including R&D, manufacturing, and service.

Request CalibrationRequest Repair
Product Starting From:

$1,150.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 4200-6E
Equipment info

The Boonton 4200-6E is a single-channel RF power sensor designed for accurate and reliable power measurements. It is part of the Boonton 4200 series, a microprocessor-controlled RF power meter system that accepts various sensors to provide measurements across a broad frequency and power range. The 4200-6E sensor specifically operates within a defined frequency and power range, compatible with the Boonton 4200 power meter.

### Technical Specifications

* **Frequency Range:**
* 100 kHz to 18 GHz
* The Boonton 4200 meter system, in general, has a frequency coverage from 100 kHz to 110 GHz, dependent on the sensor used.
* **Power Range:**
* 100 nW to 1 W (-40 dBm to +30 dBm)
* Can measure up to 5 W (+37 dBm) with an optional 20 dB attenuator.
* The general sensor capabilities for the 4200 series range from 0.1 nW (-70 dBm) to 5 W (+37 dBm), sensor dependent.
* The true RMS detection area for the 4200-6E sensor is specified as -40 dBm to 0 dBm, which can be extended with attenuation.
* **Measurement Rate:**
* 20 measurements per second.
* **Accuracy:**
* Basic Uncertainty (for 6E sensor): 1.2% reading + 0.1% full scale.
* The total measurement uncertainty of the Model 4200 system is the sum of instrumentation uncertainty, noise, reference frequency, and sensor-specific uncertainties.
* **Calibration:**
* Stored calibration data for up to 8 sensors can be held in the non-volatile memory of the Boonton 4200 meter.
* Calibration factors can be entered through the front panel, and the system automatically applies them when the measurement frequency is entered.
* The 4200 meter has a built-in, NBS traceable 1 mW, 50 MHz reference for convenient calibration.
* A CAL key on the 4200 meter activates automatic sensitivity adjustment to align with the power reference. The range of correction is limited to ±7.5% to prevent calibration of faulty sensors.
* **Resolution:**
* Power can be displayed in Watts or dB with a resolution of 0.01 dB.
* **Ranging:**
* Autoranging is standard, with an option to hold the current range.

### Electrical Characteristics

* **Power Reference:**
* Internal 50 MHz oscillator with a Type N female connector on the front panel.
* Power Output: 1.00 mW.
* **Calibration Factors:**
* Range: 3.0 dB to -3.0 dB in 0.01 dB steps.

### Interfaces

* **Sensor Connector:** Type N female (typical for sensors).
* **GPIB Interface (Optional):**
* Option -01B for IEEE-488 Bus Interface.
* Duplicates all front panel controls except the power switch.
* Allows selection and zeroing of individual power and dB ranges.
* Address and termination characters are set via rear panel bit switch.
* Complies with IEEE-488 standards (SH1, AH1, T6, L4, SR1, RL1, DC1, DT1).
* **Recorder Output:**
* Watt Mode: 10 volts full-scale, proportional to indicated power over each range.
* dB Mode: 8 volts equivalent to 0 dBm.
* The DC output is linear with power in power mode and linear in dB in dB mode, with a sensitivity of 1 volt per 10 dB change.
* **TTL Logic Level Output:** Activated during the zeroing sequence, can be used to turn off a connected source.

### Physical Characteristics

* **Dimensions (Boonton 4200 Meter):**
* Height: 5.85 in (14.9 cm).
* Width: 8.3 in (21.1 cm).
* Depth: 13.75 in (34.9 cm).
* **Weight (Boonton 4200 Meter):** 10 lbs (4.54 kg).

### Compatibility

* **Boonton 4200 Series:** The 4200-6E is designed to be used with the Boonton 4200 RF power meter.
* **Power Sensors:** The Boonton 4200 meter system can accept up to 13 different power sensors. The 4200-6E is one such sensor. Other sensors mentioned include 4200-4E, 4200-5E, 4200-7E, 4200-8E, and waveguide sensors.
* **Cabling:** A 5-foot power sensor cable (Model 41-2A) is typically supplied with each sensor ordered.
* **Impedance:** Sensors are calibrated for use with a 50-ohm source. Using a 75-ohm source can result in increased SWR and affect measurement accuracy, which can be mitigated with a low-SWR attenuator or tuner.

Why Choose Aumictech for Boonton 4200-6E?
At Aumictech, we specialize in supplying high-end RF and microwave test equipment. Whether you need precise RF power measurements, reliable sensor compatibility for your Boonton 4200 system, or integrated solutions for R&D and manufacturing, our team ensures the Boonton 4200-6E delivers maximum performance for your application.