The California Instruments 18000LX/3 is a high-power AC power source and analyzer designed for comprehensive AC power testing. It offers a flexible AC power source combined with a high-end harmonic power analyzer, capable of addressing applications that would typically require multiple instruments. The Lx Series, including the 18000LX/3 model, is microprocessor-controlled and can be operated from a front panel keypad, with analog controls for dynamic slewing of output voltage and frequency. This series is known for precise output regulation and accuracy, high load drive current, and multi or single-phase operation. It supports SCPI command language programming and is equipped with IEEE-488 (GPIB) and RS232C remote control interfaces.
**Technical Specifications**
**General:**
* **Model:** 18000LX/3
* **Series:** Lx Series II
* **Type:** Programmable AC Power Source / Analyzer
* **Power Rating:** 18 kVA
* **Phase Configuration:** 3-Phase (also available in single-phase configurations)
* **End of Life Notice:** The Lx series has an End of Life notice with a last buy date of June 30, 2019, and last shipments at the end of 2019. The suggested replacement is the California Instruments Asterion series.
**Electrical Specifications:**
* **Input Voltage:**
* 400V (Line to Line, three-phase, delta or wye)
* 208-230V (Line to Line, three-phase, delta or wye)
* Note: All input voltage specifications are for Line to Line three phase.
* **Output Voltage Ranges:**
* Standard: 0-150V, 0-300V (Line to Neutral)
* -HV Option: 156/312 V (Line to Neutral)
* -EHV Option: 200/400 V (Line to Neutral)
* For three-phase configurations, all specifications are for Line to Neutral (L-N).
* Maximum Line to Line voltages: 467V (standard), 540V (-HV option), 692V (-EHV option).
* **Output Frequency:**
* Standard models (3000Lx, 4500Lx, 6000Lx): Up to 5000 Hz.
* Multi-chassis models (9000Lx/2, 12000Lx/2, 13500Lx/3, 18000Lx/3): Up to 2000 Hz.
* -HF Option: Extends upper frequency limit.
* -LF Option: Limits output frequency to 500 Hz.
* **Current:**
* For three-phase configurations, current specifications are for L-N.
* 1-Phase Load Current (3 boxes): 48 amps (16A per phase), 72 amps (24A per phase), 60 amps (20A per phase), 90 amps (30A per phase), 42 amps (14A per phase), 63 amps (21A per phase).
* 3-Phase Load Current: 16 amps, 24 amps, 20 amps, 30 amps, 14 amps, 21 amps.
* **Power Factor:** 0 to unity at full output VA.
* **Load Regulation:** < 0.1% FS
* **Line Regulation:** < 0.02% for 10% line change
* **Waveform Generation:**
* Standard Waveforms: Sinewave, Squarewave, Clipped Sinewave (simulates THD levels).
* User-defined arbitrary waveforms can be downloaded over the bus.
* Harmonic waveforms can be generated to test for harmonics susceptibility.
* **Total Harmonic Distortion (THD):**
* Standard: Specify sine wave with resistive load.
* Specifications apply after a 30-minute warm-up period.**Measurement and Analysis Capabilities:**
* **Measurement System:** Based on real-time digitization of voltage and current waveforms using a 4K sample buffer.
* **Processing:** Digital Signal Processor (DSP) for extracting conventional load values and performing Fast Fourier Transformation (FFT).
* **Measured Parameters:** RMS voltage, RMS current, real power, apparent power.
* **Harmonic Analysis:** Amplitude and phase angle of up to 50 harmonics.
* **Built-in Power Analyzer:** Performs voltage and load current harmonic analysis and waveform acquisition.**Interfaces:**
* **Remote Control:**
* IEEE-488 (GPIB) Interface (standard)
* RS232C Interface (standard)
* USB Interface (standard)
* Optional Ethernet LAN Interface
* **Programming Language:** SCPI command language support.
* **Other:**
* Remote Inhibit Function.
* RPV Input (RPV option).**Physical:**
* **Chassis Configuration:** Multi-chassis configuration for 18000LX/3.
* **Rack Mountable:** High efficiency, rack mountable design.**Compatibility:**
* **Backward Compatible:** Compatible with HP6834B & iL Series AC Sources Function & bus compatible with the Agilent HP6834B & California Instruments iL Series.**Environmental:**
* **Operating Temperature:** Specifications are warranted over an ambient temperature range of 25°± 5° C.**Safety:**
* **Hazardous Voltages:** Hazardous voltages may be present when covers are removed. Qualified personnel must use extreme caution when servicing. Capacitors may retain an electrical charge even when power is off.
* **Grounding:** Ensure that the AC power line ground is connected properly.
* **ESD Sensitive:** The equipment contains ESD sensitive ports. Follow ESD Safety Procedures during installation.Why Choose Aumictech for California Instruments 18000LX/3?
At Aumictech, we specialize in supplying high-end AC power source equipment. Whether you need precise output regulation, advanced harmonic analysis, or seamless ATE system integration, our team ensures the California Instruments 18000LX/3 delivers maximum performance for your application.