Fluke Impulse 7000DP Defibrillator Analyzer and Pacemaker Tester

SKU: 7000DPCategories: Calibration Equipment
Brand: Fluke
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

The Fluke Impulse 7000DP Defibrillator Analyzer and Pacemaker Tester is a comprehensive tool for testing and troubleshooting defibrillators and external pacemakers. It offers accurate and reliable performance analysis to ensure medical devices meet safety and functionality standards. This analyzer evaluates energy output, pulse characteristics, and pacing parameters, making it essential for biomedical engineers and technicians. Its user-friendly interface and robust design facilitate efficient testing in clinical and field environments.

Request CalibrationRequest Repair
Product Starting From:

$6,279.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 7000DP
Equipment info

The Fluke Impulse 7000DP is a defibrillator analyzer and pacemaker tester engineered to validate the performance and safety of defibrillators and external pacemakers across clinical and field environments. Designed for biomedical and clinical engineers, the instrument measures energy output, waveform characteristics, synchronization timing, charge times, and pacemaker parameters with high precision. It simulates 12-lead ECG signals and supports all major defibrillator technologies, making it essential for device maintenance and regulatory compliance.

## Technical Specifications

### Defibrillator Analysis

**Energy Output Measurement**
• Range: 0.1 J to 600 J
• Accuracy: ±1% of reading + 0.1 J (0.1 J to 360 J); ±(1.5% of reading + 0.3 J) for pulsed biphasic waveforms

**Waveform Compatibility**
Supports Lown, Edmark, trapezoidal, biphasic, and pulsed-biphasic defibrillation technologies, plus AED implementations.

**Synchronization Testing (Elective Cardioversion)**
• Delay measurement window: ECG R-wave peak to defib pulse peak
• Range: −120 ms to 380 ms
• Resolution: 1 ms
• Accuracy: ±1 ms

**Charge Time Testing**
Measures and customizes defibrillator charge times.

**ECG Waveform Simulation**
• 12-lead ECG with 10 independent outputs for complete lead combinations
• Normal sinus rhythm: 10 BPM to 180 BPM in 1 BPM increments
• Monomorphic ventricular tachycardia: 120 BPM to 240 BPM in 5 BPM steps
• Atrial fibrillation (coarse and fine), asystole, and ventricular fibrillation
• NSR amplitude: 0.05 mV to 0.45 mV (0.05 mV steps) and 0.5 mV to 5 mV (0.5 mV steps)
• Transcutaneous ECG NSR: 0.05 mV to 0.95 mV amplitude; 10 BPM to 300 BPM in 1 BPM steps; accuracy ±5% of setting

### Pacemaker Analysis (7000DP)

**Pacer Parameter Testing**
Measures and customizes pacemaker settings and refractory periods.

## Key Features

• Autoranged measurement from 0.1 J to 360 J with optimized accuracy
• Millisecond-precision synchronization timing for cardioversion validation
• User-friendly interface for efficient operation in varied clinical settings
• Support for both standard and specialized waveform technologies

## Compatibility & Integration

The 7000DP validates modern AED devices and legacy defibrillators using established waveform technologies. ECG simulation accommodates standard 12-lead recording conventions and transcutaneous pacing scenarios.