The TDK-Lambda GENH 300-2.5 is a 750 W programmable AC-DC power supply from the Genesys™ series, engineered for OEM, industrial, and laboratory applications requiring precise DC output control. This 1U rack-mount unit delivers 0–300 Vdc at 0–2.5 A with exceptional voltage stability: 0.025 Vrms ripple and 87% typical efficiency. Universal single-phase input (85–265 VAC, 47–63 Hz) with active power factor correction (0.99 typical at full load) ensures global deployment capability.
## Technical Specifications
**Input**
• Single-phase AC: 85–265 VAC, 47–63 Hz
• Active power factor correction: 0.99 (typical, full load)
**Output**
• Voltage: 0–300 Vdc (rated 300 Vdc)
• Current: 0–2.5 A (rated)
• Power: 750 W
• Ripple/noise: 0.025 Vrms, 0.013 Arms (5 Hz–1 MHz)
• Efficiency: 87% (typical)
**Protection**
• Overvoltage protection (OVP), undervoltage limit (UVL), and current foldback—all adjustable
• Selectable output latch-off on fault event
• Safe restart and memory retention of last settings
**Physical**
• 1U form factor: 214 mm W × 43.6 mm H × 437.5 mm D
• Weight: 4500 g typical
• Operating temperature: 0–50°C
## Key Features
• Remote sensing to compensate output cable voltage drop
• Analog programming: 0–5 V or 0–10 V (selectable)
• Remote ON/OFF and Enable/Disable control
• RS-232 and RS-485 standard; optional LAN (LXI), USB, GPIB (IEEE 488.2), and isolated analog I/O
• SCPI command protocol and multi-drop RS-485 addressing (up to 31 units daisy-chained)
• IEC61010-1, CSA C22.2 No.61010-1, EN61010-1, UL61010-1 certified; CE/UKCA marked
## Typical Applications
Electronic equipment testing, materials characterization, power electronics validation, and laboratory system integration where flexible voltage/current adjustment and networked control are required.
## Compatibility & Integration
Communicates via standard RS-232/RS-485 or optional LAN, USB, and GPIB interfaces. Supports SCPI commands and isolated analog feedback loops for seamless multi-instrument test benches.