The Lambda/TDK EMI LK351 is a single-stage EMC filter designed to reduce both common mode (CM) and differential mode (DM) noise in power electronic systems. This filter is ideal for use in various applications, including industrial equipment, medical devices, and telecommunications systems, ensuring compliance with stringent EMC standards. It features a compact design and reliable performance.

Request CalibrationRequest Repair
Product Starting From:

$340.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote LK351
Equipment info

The TDK-Lambda EMI LK351 is a programmable DC power supply and single-stage EMC filter engineered to suppress both common-mode and differential-mode noise across industrial, medical, and telecommunications applications. This 900 W unit delivers 0–36 V DC at up to 25 A with exceptional regulation stability and rapid transient response, meeting stringent EMC compliance requirements through conducted emissions mitigation up to 30 MHz.

Technical Specifications

Input voltage ranges from 85–265 V AC (single-phase) at 47–63 Hz. Output is programmable 0–36 V DC at 0–25 A, yielding 900 W maximum power. Line regulation holds ≤0.01% of full scale (or 0.015% or 1 mV, whichever is greater) across 105–132 VAC. Load regulation maintains the same tolerance for no-load to full-load transitions. Output ripple and noise measures ≤10 mV RMS or ≤0.5 mV RMS when either positive or negative terminal is grounded, or less than 1 mVrms. Voltage programming accuracy is ≤0.1% of rated output; current accuracy is ≤0.2% of rated output. Transient response time is ≤1 ms for 50–100% load changes. Typical efficiency exceeds 85%.

– Key Features

• Automatic crossover constant-current regulation with voltage limit
• Adjustable overcurrent protection, settable to 105% of rated current
• Overvoltage and overtemperature protection with automatic thermostat reset
• Internal fuse protection against internal failures
• Front-panel coarse and fine voltage and current adjustment controls
• Digital voltmeter and ammeter display
• Remote sensing provision to eliminate power output lead resistance effects
• Remotely programmable by voltage or resistance input on all models
• Convection cooling with internal fan for forced air circulation

– Thermal Performance

Operating temperature range: 0°C to +71°C continuous at rated load, or 0°C to +71°C ambient with tabulated derating. At 50 Hz operation, derate output current by 10%. Storage temperature: −55°C to +85°C.

– Physical & Integration

1U, 19-inch rack-mountable chassis measuring 5-3/16″ × 19″ × 16-1/2″ (140 × 124 × 350 mm), weighing approximately 4.5 kg. Brushed aluminum panel with grey inlay (standard). Rear terminal block for AC input and DC output connections. Power control via front-panel on/off switch or circuit breaker.

MPN

LK351

Frequency Range

47–63 Hz

Voltage / Current Range

0–25 A, Input: 85–265 V AC; Output: 0–36 V DC

Brand Name

Lambda / TDK