Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Midtronics CTM-300

SKU: CTM-300Categories: Calibration Equipment
Brand: Midtronics
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

The Midtronics CTM-300 Celltron Module Test Meter is a handheld device designed for testing the conductance of individual cells or modules in large battery systems. It provides accurate and reliable measurements to assess battery health and identify weak or failing cells, ensuring optimal performance and longevity of the battery system.

Request CalibrationRequest Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote CTM-300
Equipment info

The Midtronics CTM-300 Celltron Module Test Meter is a handheld conductance-based battery analyzer for testing individual cells or modules within lead-acid battery systems. It uses proprietary conductance testing to assess battery health and identify weak or failing components without discharging the battery. Results are displayed in Siemens (G), Mhos, or as a percentage of reference conductance value.

Technical Specifications

• Measurement Principle: Conductance (Ohmic value)
• Units of Measure: Siemens (G), Mhos, Percentage (%) of reference
• Battery Types: Single cell through six-cell lead-acid batteries (2 V to 12 V DC)
• Operating Voltage Range: 1.0 V to 15 V DC
• Amp Hour Range: Approximately 5 Ah to 2000 Ah
• Conductance Measurement Range: 100–6,000 Mhos/Siemens (single cell); 100–10,000 Mhos/Siemens (multiple cell)
• Conductance Accuracy: ±2% across test range
• Voltmeter Resolution: 10 mV DC or ±20 mV DC
• Temperature Compensation: 0 °C to 35 °C
• Power Source: One 9 V alkaline battery
• DC Power Consumption: <3 W
• Over Voltage Protection: Fused to 60 V DC
• Current Load: <0.001 Ah per test; <1 A during each test
• Data Storage: 252 consecutive test results
• Dimensions: 9" × 4" × 2.5" (230 mm × 102 mm × 65 mm)

– Key Features

• Non-destructive on-line testing—no battery discharge required
• Reverse polarity protection; diode-protected design prevents operation when connected backward on 2 V–12 V DC batteries
• Temperature-compensated results from 0 °C to 35 °C
• Programmable presets for up to 31 battery types with user-definable reference numbers and fault thresholds
• Configurable low voltage alarm, low conductance warning, and low conductance failure settings
• Day/date/time logging (USA and International formats); push button or auto-start test modes
• Housing materials resist sulfuric acid, petroleum products, and no-Ox grease
• Impact-rated design: tested for drop resistance from one meter onto concrete across all six axes

– Data Output & Integration

• Infrared (IR) wireless printing via included IR Printer (Part #A050)
• PC data transfer through optional C060 Accessory Interface Unit with Windows-compatible software

– Typical Applications

Stationary and standby battery system testing; cell-by-cell monitoring in multi-cell lead-acid batteries; condition assessment of backup power systems without operational interruption.

MPN

CTM-300

Voltage / Current Range

1.0 V to 15 V DC; <0.001 Ah per test; <1 A during each test

Brand Name

Midtronics

You May Also Like

Can't Find The Right Product? Contact Us.