The National Instruments PXI-1006AC is an 18-slot, 3U PXI chassis designed to support high-module-count modular instrumentation, data acquisition, and control applications. It accommodates both standard PXI and CompactPCI modules with a high-performance backplane featuring integrated timing, triggering, and local bus connectivity. The chassis delivers up to 600 W of usable power and combines efficient thermal management with flexible trigger distribution across three PXI segments, making it suitable for synchronized, demanding test and measurement environments.
Technical Specifications
• Slots: 18 PXI slots (slots 1 and 2 exclude local bus connections per PXI specifications; slot 1 designated as system controller slot)
• Compliance: PXI Specification, Revision 2.0
• System Clock: Independent 10 MHz reference clock (PXI_CLK10) to each peripheral slot; external clock input via PXI_CLK10_IN pin on star trigger slot P2 connector; supports synchronization of up to 17 modules
• Trigger Bus: Eight trigger lines on PXI trigger bus; star trigger bus with independent line per slot at less than 1 ns skew; three PXI segments with corresponding trigger bus divisions
• Power Supply: 600 W usable output; universal AC input 90–264 VAC; 47–63 Hz frequency range; removable modular unit with integrated fans; 10 A AC circuit breaker; DC over-current protection at 105–140% of rated output with automatic recovery
• MTTR: Less than 5 minutes (modular power supply)
• Operating Temperature: 0–50 °C
• Power Monitoring: Remote power inhibit and monitoring via 9-pin D-sub rear panel connector
– Key Features
• Integrated cooling supporting wide module range
• Star trigger architecture with minimal skew for precise synchronization
• Flexible PXI segment configuration for trigger line distribution
• Quick-service modular power supply design
• AC input protection and DC output fault recovery
– Typical Applications
• Multi-module synchronized test systems
• High-channel-count data acquisition
• Real-time control and instrumentation platforms
• Demanding laboratory and production test environments
– Compatibility & Integration
Accepts standard PXI and CompactPCI modules. Slot 1 reserved for system controller. External clock synchronization available through dedicated connector on star trigger slot.