The NH Research S6000-2x300W is a modular, card-based test system for high-volume power conversion device testing. It integrates configurable source and load modules with distributed measurement capability on each channel, enabling parallel measurements and reduced test times. The embedded digitizing measurement system captures static and transient data from a single waveform, replacing separate voltmeter, timing analyzer, power analyzer, and oscilloscope instruments.
Technical Specifications
Measurement Architecture
• Distributed measurements: Two isolated channels per load channel
• Digitizing capability: 1 MS/s sampling rate
• Record length: 256K points
Power Analyzer Measurements
• Voltage: 600 VDC, 350 VRMS, Vpk+, Vpk−
• Current: 20 ADC, 20 ARMS, Ipk+, Ipk−
• Power metrics: Average, True, Apparent, Reactive, Power Factor
• Frequency measurement range: 10 Hz to 1000 Hz
• Waveform analysis: Rise Time, Fall Time, Settling Time, Turn-On Time, Hold-Up Time, Time Event, THD
• Timing triggers: Trigger In, DIN State & Time
Modular Load Configurations
• Available power ratings: 150W, 300W, 600W for 120V and 500V configurations
• Extended range: 1 kW to 6 kW for 120V and 600V loads
• Load module example: 4312-300 (300W, 0.6−120 VDC, 80A, 2 slots)
• Load module example: 4350-300 (300W, 2.3−500 VDC, 60A, 2 slots)
Modular DC Source Options
• 6102: 450W, 0−20 VDC, 60A, 1 slot
• 6104: 450W, 0−40 VDC, 30A, 1 slot
• 6108: 450W, 0−80 VDC, 15A, 1 slot
• 6145: 450W, 0−450 VDC, 8A, 1 slot
AC/DC Sources (Model 9420)
• Power ratings: 4 kW, 8 kW, 12 kW
• Configurable single, split, or 3-phase output
• Power line disturbance programming capability
• Energy Star low-current measurement support
– Key Features
• Chassis-based modular architecture for flexible configuration
• Parallel measurement capability across multiple load channels
• Single waveform capture yields static and transient analysis
• emPower® Test Executive with production-ready test routines and report templates
– Compatibility & Integration
• ActiveX/COM interface standards support
• SCPI command control via Ethernet (TCP/IP) with unique IP addressing
• Compatible with internal network communication and reporting protocols