The NI PR27-30F Cable (1 Meter) is a shielded industrial fieldbus cable engineered for process control, petrochemical, and subsurface applications. Dual-screened twisted-pair construction with tinned copper conductors, individual pair shielding, and comprehensive outer protection deliver exceptional EMI rejection and signal integrity in harsh environments. 300 V nominal rating with flame-retardant or LSZH jacketing options supports installation in cable trays, conduits, buried ducts, and hydrocarbon-rich settings.
Technical Specifications
• Conductor: Tinned coated annealed copper per IEC 60228 (Class 1 solid, Class 2 stranded, or Class 5 flexible)
• Insulation: XLPE or FRXLPE per EN50290-2-29
• Pair Configuration: Uniformly twisted insulated conductors with individual aluminum-backed Mylar screen (25 µm, 25% overlap) and 0.5 mm² tinned copper drain wire (7×0.3 mm)
• Collective Screen: Aluminum-backed Mylar (25 µm, 25% overlap) with 0.5 mm² annealed tinned copper drain wire over full assembly
• Inner Sheath: FR-PVC per EN50290-2-22 or LSZH per EN50290-2-27
• Lead Sheath: Lead alloy per EN50307
• Bedding: FR-PVC per EN50290-2-22 or LSZH per EN50290-2-27
• Armor: Galvanized Steel Wire Armor (GSWA) or Double Galvanized Steel Tape (DGST) per EN10257-1
• Outer Sheath: FR-PVC per EN50290-2-22 or LSZH per EN50290-2-27
• Nominal Voltage: 300 V
• Test Voltage: 2000 V
• Insulation Resistance: ≥5 GΩ·km
• Mutual Capacitance: 0.5/0.75/1 mm² ≤115 pF/m; 1.5/2.5 mm² ≤120 pF/m
• Operating Temperature: −15°C to +90°C
• Installation Temperature: −5°C to +50°C
• Minimum Bending Radius: 20× overall diameter
• Length: 1 meter
• Sheath Color: Black or Blue
• Marking: Meter marked
– Key Features
• Dual-layer screening architecture minimizes crosstalk and external interference
• Lead alloy sheath provides mechanical protection and chemical resistance
• LSZH option reduces toxic gas and smoke evolution in fire events
• Compliant with IEC 61158-2 Type-A, BS EN 50288-7, IEC 60332-3, and ASTM D 2863-13
• Halogen content verified per IEC 60754-1
– Typical Applications
Trunk and spur fieldbus systems in process controls, refineries, oil and gas facilities, and petrochemical plants. Suitable for cable trays, conduit routing, buried and underground duct installations with inherent hydrocarbon resistance.
– Compatibility & Integration
Designed for industrial control networks and process automation systems requiring superior noise immunity and long-term reliability in corrosive or chemically aggressive environments.