The Qualmark OVS-3 (Typhoon 3.0) is a combined thermal and vibration testing system for HALT and HASS applications. It delivers extreme temperature cycling from +200°C to -100°C paired with six-degree-of-freedom random vibration to expose design weaknesses and manufacturing defects. The 36″ × 36″ table accommodates mid-sized to larger products with flexible chamber volume adjustment via dual table heights.
Technical Specifications
• Part Number: 971-4030
• Vibrational Table: 36″ × 36″ (914 mm × 914 mm), 10 lubricant-free actuators
• Excitation: Six-degree-of-freedom (6DoF) random broadband (OmniAxial™), 10 Hz to above 5,000 Hz
• Acceleration: 5–70 gRMS typical; greater than 100 gRMS available on special order
• Table Capacity: 450 lb (204 kg); custom higher capacities available
• Temperature Range: +200°C to −100°C (+392°F to −148°F)
• Thermal Ramp Rate: 70°C/min average or 70–100°C/min average (measured −65°C to +85°C in open air 3″ above table center)
• Heating: Open-element nichrome type
• Cooling: Vacuum-jacketed liquid nitrogen (LN2) injection
• Work Space (Lower Position): 44.0″w × 45.0″d × 35.0″h (1,118 mm × 1,143 mm × 889 mm)
• Work Space (Upper Position): 44.0″w × 45.0″d × 25.0″h (1,118 mm × 1,143 mm × 635 mm)
• Interior Volume: Approximately 40.1 cu. ft. (1,135 liters)
• Outer Dimensions: 56.1″w × 69.6″d × 88.1″h (1,759 mm × 1,768 mm × 2,237 mm)
• Table Mounting: 81 threaded holes 3/8-16 on 4″ centers (M10 optional)
– Key Features
• PLC-based control with Microsoft Windows and LabVIEW-based Typhoon Manager Software
• One control accelerometer; three additional input channels available
• Two 72″ thermocouples provided (product and air); four additional input channels available
• Power Spectral Density (PSD) monitoring with factory specification reset
• Dual table height positions for chamber volume adjustment
– Typical Applications
HALT (Highly Accelerated Life Testing) and HASS (Highly Accelerated Stress Screening) for product reliability and quality assurance.
– Compatibility & Integration
Data logging, programming, and operation via Typhoon Manager Software. Supports extended sensor integration through additional thermocouple and accelerometer channels.