The Rohde & Schwarz NRP-Z81 is a wideband power sensor for precise RF power measurements across 50 MHz to 18 GHz. It delivers 1 nW to 100 mW dynamic range with high-speed acquisition—up to 50,000 readings per second—and sub-nanosecond rise/fall time (13 ns typical). The sensor combines RF detection, analog/digital signal processing, and analysis logic in a compact unit controlled via USB or R&S NRP base station.
Technical Specifications
• Frequency Range: 50 MHz to 18 GHz (50 MHz to 500 MHz with reduced video bandwidth)
• Power Range: 1 nW to 100 mW (−60 dBm to +20 dBm)
• RF Connector: N-type plug
• Measurement Speed: Up to 50,000 readings/s; 9,500+ measurements/s buffered mode
• Video Bandwidth: 30 MHz (typical 20 MHz below +15 °C)
• Rise/Fall Time: <13 ns (11 ns for high-resolution envelope analysis)
• Pulse Detection: 50 ns minimum pulse width; automatic rise/fall time, pulse width, duty cycle, and period measurement
• Statistical Analysis: CCDF/CDF/PDF computation on 1 million samples in <25 ms at full video bandwidth
• Dynamic Range: 80 dB average power, 70 dB peak power
• Zero Drift: <1 nW
• Sampling Rate: 80 Msample/s with 12.5 ns time resolution; 100 ps equivalent time sampling available
• Operating Temperature: +15 °C to +50 °C
– Key Features
• Envelope power detection down to −47 dBm; average power to −60 dBm
• Automatic pulse parameter extraction including start/stop time and pulse off time
• Peak-to-average power ratio (PAPR) and amplitude distribution analysis
• 80 dB dynamic range for average power measurement
– Typical Applications
• Radar systems and pulse characterization
• Microwave link module power verification
• OFDM/CDMA component design and validation (EUTRA/LTE, 3GPP FDD)
– Compatibility & Integration
N-type RF input connector. Direct USB remote control via PC or operation with R&S NRP/NRP2 base units using circular plug-in connector.