The TDK-Lambda 02003 is a mountable AC-DC power supply engineered for industrial and commercial applications requiring stable, regulated output with field-adjustable voltage control. This unit delivers up to 5A maximum load current from a wide input voltage range and integrates external fuses, J1 Molex connector, and remote sensing capability for precision voltage regulation.
Technical Specifications
• Model: TDK-Lambda 02003
• Product Type: AC-DC Power Supply
• Series: Case 02/03/04
• Input Voltage Range: 85–265 VAC, 47–63 Hz (100–240 VAC, 50–60 Hz for specific safety compliance); output power derating required below 115 VAC
• Maximum Load Current: 5 A
• Output Voltage Adjustment: Via V. ADJ trimmer (VR51); clockwise rotation increases voltage
• Isolation Resistance: >100 MΩ at 500 VDC (Output – terminal)
• Inrush Current Protection: Power thermistor
• Connector: J1 Molex
– Key Features
• External fuses for circuit protection
• Remote sense output voltage adjustment
• Power thermistor inrush current limiting
• Parallel backup operation capability (Method B) with blocking diode configuration
• Field-adjustable output voltage via onboard trimmer
– Operating Conditions & Limitations
Avoid frequent input on/off cycling due to surge current stress. Input wiring must connect to correct terminals to prevent damage. Operation outside specified input voltage, output current, ambient temperature, and humidity ranges may cause product failure. Do not operate or store in condensation-prone environments without waterproof treatment. Environments with strong electromagnetic fields, corrosive gases, or conductive substances are unsuitable. For mission-critical applications (nuclear, medical, traffic control), implement fail-safe mechanisms in end equipment. Do not inject abnormal voltages into output or signal lines.
– Compatibility & Integration
Parallel backup operation requires output voltage adjustment to compensate for blocking diode forward voltage drop (VF), with each supply adjusted to identical output voltage. All supplies must remain within rated output voltage and power specifications. Blocking diodes must have current ratings exceeding maximum load current to prevent reverse current flow.