The Velonex 587 is a voltage and current surge generator engineered to meet ANSI/IEEE C62.41-1980, IEC 664-1980, IEC 801-5, and ANSI/IEEE 62.41-1991 standards. It generates three distinct waveforms for comprehensive low-voltage AC power circuit surge testing: an oscillatory ring wave, an open-circuit exponential waveform, and a short-circuit exponential waveform. The unit operates from 115 VAC, 50/60 Hz single-phase power and delivers three front-panel selectable surge outputs with independently selectable polarity.
Technical Specifications
Output Waveforms:
• Oscillatory waveform (ring wave): 6 kV, 100 kHz
• Open-circuit exponential waveform: 6 kV, 1.2 × 50 µs
• Short-circuit exponential waveform: 3 kA, 8 × 20 µs
Trigger and Synchronization:
• Non-synced repetition: approximately 0.04 Hz (one surge every 25 seconds) in 3 kA mode; 1 Hz in 6 kV modes
• Line-sync and external trigger capable
• External trigger input via front-panel BNC: 2.5 V to 10 V peak, 0.5 µs minimum width, positive polarity; input impedance approximately 6000 Ω
Monitoring:
• Ground-isolated voltage monitor output with scope trigger capability
• Current monitor output
• Front-panel digital voltmeter for peak output voltage indication
• Ready-to-test indicator
Power Requirements:
• Input: 115 VAC, 50/60 Hz, 1 A
– Key Features
• Three independently selectable waveform outputs from single chassis
• Positive or negative polarity selection via floating output configuration
• Continuous Dual Waveform mode available (Option “T”)
• Extended operational voltage via Option “p” (480 V RMS capable)
• DC isolation capability to 50 V, 20 A available (Option “D”)
– Typical Applications
Surge immunity and transient testing in low-voltage power distribution systems, equipment input protection validation, and regulatory compliance verification for AC-powered devices and circuits.
– Compatibility & Integration
The Velonex V-2980 Surge Coupling Isolation Network is available as a companion accessory for enhanced performance in complex test configurations. The V-2980 accommodates both AC and DC operational modes with selectable isolation network impedance and dual voltage monitoring.