The Advantech PCL-81601 is a modular data acquisition card built for industrial measurement and control in demanding environments. It combines a 16-bit ADC with 100 kHz sampling capability, 16 differential analog inputs, 16 digital I/O channels, and two expansion slots for functional modules. The metal-shielded A/D module and DB-37 connector deliver signal integrity critical to noise-sensitive applications.
Technical Specifications
Analog Input
• 16 differential channels, 16-bit resolution
• Maximum sampling rate: 100 kHz
• Conversion time: 8.5 µsec
• Software-programmable gains: 1, 2, 4, 8
• Input ranges (bipolar): ±10 V, ±5 V, ±2.5 V, ±1.25 V
• Input ranges (unipolar): 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V
• Accuracy: ±0.003% ±1 LSB
• Input impedance: > 10 MΩ
• Overvoltage protection: ±15 V
• Trigger modes: Software, pacer, external
• Data transfer: Software, interrupt (IRQ 2–7), or DMA (channels 1 or 3)
Digital I/O
• 16 TTL-compatible input channels (0.8 V max. for logic 0; 2.0 V min. for logic 1)
• 16 TTL-compatible output channels (0.4 V max. @ 16 mA sink; 2.4 V min. @ 800 mA source)
• 20-pin flat cable connectors
Timer/Counter
• Intel 8254 programmable pacer clock
• 10 MHz time base
• Maximum rate: 2.5 MHz
• Minimum rate: 0.00023 Hz
– Key Features
• Metal-shielded A/D module for enhanced noise rejection
• Flexible input range and gain selection via software
• Two 64-pin piggyback connectors for expansion modules
• Optional PCL-816-DA analog output module (2-channel 16-bit D/A, ±10 V bipolar, 5 µsec settling time)
• DB-37 shielded connector for signal integrity
– Typical Applications
Multichannel industrial data logging, process control systems, environmental monitoring, laboratory instrumentation, and closed-loop control requiring high-resolution analog acquisition with synchronized digital signaling.
– Compatibility & Integration
Supported by Windows DLL drivers and ActiveX controls. Compatible with Visual BASIC, Microsoft Visual C++, Borland C++, Delphi, and LabVIEW environments.