The Agilent/Keysight N8975AZ is a high-performance noise figure analyzer designed for accurate and repeatable noise figure measurements. This instrument offers a frequency range of 10 MHz to 26.5 GHz in a single unit. It is engineered for ease of use, enabling users to set up complex measurements efficiently, leading to reliable and repeatable results. The N8975AZ facilitates simultaneous noise figure and gain measurements, with the capability to display, print, and save data in various formats. This analyzer is also adept at characterizing amplifiers and frequency translating devices, including local oscillator (LO) control over a dedicated GPIB interface. Advanced calibration techniques and a user-friendly interface contribute to its suitability for demanding applications. For extended frequency coverage up to 110 GHz, the N8975A platform supports K-Series block downconverters.
### Technical Specifications
**Frequency Range:**
* 10 MHz to 26.5 GHz (standard configuration)
* Can be extended up to 110 GHz with K-Series block downconverters.
* N8975AZ-K40: 26.5 GHz to 40.0 GHz
* N8975AZ-K50: 36.5 GHz to 50.0 GHz
* N8975AZ-K63: 50 GHz to 63.5 GHz
* N8975AZ-K67: 58 GHz to 67 GHz
* N8975AZ-K75: 61.5 GHz to 75.0 GHz
* N8975AZ-K88: 75 GHz to 88.5 GHz
* N8975AZ-K98: 86.5 GHz to 100 GHz
* N8975AZ-K99: 96.5 GHz to 110.0 GHz
**Measurement Capabilities:**
* Simultaneous noise figure and gain measurements
* Characterization of amplifiers and frequency translating devices
* LO control over dedicated 2nd GPIB
* Noise Figure Measurement Range: 0 to 35 dB
* Gain Measurement Range: -20 to +40 dB
**Measurement Bandwidths:**
* Six user-selectable measurement bandwidths: 4 MHz, 2 MHz, 1 MHz, 400 kHz, 200 kHz, 100 kHz
* 4 MHz measurement bandwidth is the default on all models.
**Accuracy and Performance:**
* Increased measurement accuracy and faster measurement speed compared to previous models.
* A user calibration is required before corrected measurements can be made.
* Noise figure uncertainty is approximately 0.15 dB for a 3 dB noise source.
* For accurate measurements, the noise figure plus gain of the Device Under Test (DUT) must be significantly higher than 15 dB.
* If the DUT has low gain and low noise figure, a pre-amplifier may be required for accurate measurements.
**Calibration:**
* Supports advanced calibration techniques.
* Smart noise sources simplify measurement setup and improve accuracy by automatically downloading calibration data.
* Internal calibration feature can save test time without requiring a user calibration.
* Noise figure uncertainty calculator is built-in.
* Calibration profiles can be created for multiple DUT setups in a single step, enhancing measurement efficiency.
* Performance verification and calibration guides are available.
**Noise Sources:**
* Compatible with SNS series noise sources (e.g., N4000A, N4001A, N4002A).
* Also compatible with 346 Series noise sources.
* Smart noise sources automatically download calibration data, saving time and improving reliability.
**Interfaces:**
* APC 3.5 (m) connector as standard.
* K-Series block downconverters utilize connectors such as APC 2.4(m), WR15, and WR10 depending on the frequency band.
* LO GPIB connector for controlling external LOs.
* Optionally, N-type (f) input connector.
**Physical Characteristics:**
* Dimensions (typical, without options):
* Height: 222 mm (8.74 in)
* Depth: 410 mm (16.14 in)
* Width: 375 mm (14.76 in)
* With handle (max):
* Height: 222 mm (8.74 in)
* Depth: 515 mm (20.28 in)
* Width: 409 mm (16.10 in)
* Weight (typical, without options): 17.5 kg (38.61 lbs) for N8975A model.
* Audible noise: < 42 dBa pressure and < 5.0 bels power.**Environmental Specifications:**
* Operating Temperature Range: 0° C to +55° C
* Storage Temperature Range: -40° C to +70° C
* Operating Humidity Range: Up to 95% relative humidity to 40° C (non-condensing)
* Operating Altitude Range: Up to 4,600 meters
* For indoor use only.
* Ventilation requirements must not be restricted when installed in a cabinet.**Power Requirements:**
* On (line 1): 90 to 132 V rms, 47 to 440 Hz
* On (line 1): 195 to 250 V rms, 47 to 66 Hz
* Power Consumption (On): < 300 W
* Power Consumption (Standby): < 5 W
* Class I product with a protective earthing conductor in the power cord; an external protective earthing terminal is also provided.**Compatibility:**
* K-Series block downconverters can only be used with the N8975A and N9020A MXA signal analyzers.
* Compatible with SNS series noise sources (N4000A, N4001A, N4002A).
* Compatible with 346 Series noise sources.
* Rack mount kit (5063-9240) available for mounting in a standard 19-inch EIA rack.Why Choose Aumictech for Agilent/Keysight N8975AZ?
At Aumictech, we specialize in supplying high-performance RF and microwave test equipment. Whether you need precise noise figure measurements for aerospace and defense applications, accurate characterization of amplifier performance, or reliable gain analysis for wireless communication systems, our team ensures the Agilent/Keysight N8975AZ delivers maximum performance for your application.