The Agilent/Keysight N9360A is a RF signal generator. It delivers the superior performance and essential features needed for general purpose signal generation applications. Covering a broad frequency range, it provides the flexibility and accuracy required for testing a wide variety of RF components and systems.

Request CalibrationRequest Repair
Product Starting From:

$1,500.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote N9360A
Equipment info

The Agilent/Keysight N9360A is a mobile station tester engineered for parametric and call processing measurements across GSM/GPRS/EGPRS, W-CDMA, HSDPA, cdma2000®, 1xEV-DO, and HSUPA networks. This standalone, one-box system integrates an internal PC controller with LAN and GPIB connectivity, enabling rapid protocol, RF transmitter, and receiver validation in R&D and manufacturing environments. Automated test operations require minimal operator expertise, making it ideal for service and repair workflows.

Technical Specifications

Frequency Coverage
• Band 0: 860 to 894 MHz
• Band 1: 1930 to 1990 MHz
• Band 3: 832 to 834 MHz, 838 to 846 MHz, 860 to 870 MHz
• Band 4: 1840 to 1870 MHz
• Band 5: 869 to 894 MHz
• Band 6: 2110 to 2170 MHz
• Band III: 1805 to 1880 MHz
• Band IV: 2110 to 2170 MHz

Output Power
• Power Level Range (Modulated): −115.0 to −18.0 dBm in 0.1 dB steps
• Power Level Range (CW): −115.0 to −18.0 dBm in 0.1 dB steps
• Power Level Step: 0.1 dB
• Output Power Accuracy: ≤ ±1 dB from −115.0 to −50.0 dBm at 25 ±5 °C; ≤ ±1.5 dB from −50.0 to −18.0 dBm at 25 ±5 °C

Modulation
• Supported Types: W-CDMA (QPSK), CW, FM1, CDMA
• FM Modulation: 50 kHz rate, 500 kHz deviation
• Modulation Accuracy (QPSK): ≤ 12.5% rms
• Modulation Accuracy (CDMA): > 0.990
• Residual EVM: ≤ 3.8% (0 to 10% range)

Frequency Error
• Accuracy: < ±100 kHz
• Range: 0.00 to 9.99 MHz
• Resolution: 0.01 MHz

– Key Features

• SMS test capability
• Twelve traffic-channel testing in automatic mode
• ACLR and SEM measurement capability
• Receiver sensitivity testing (GPRS ETSI A and ETSI B modes)
• EGPRS SRB loopback BLER support

– Typical Applications

"Quick check" call testing during R&D validation and protocol verification. Basic calibration testing and device characterization in manufacturing. Service and repair operations requiring rapid device assessment.

– Compatibility & Integration

Standalone architecture with internal PC controller. LAN and GPIB interfaces for integration into automated test environments.