The Agilent/Keysight SL1045A is a high-performance system component within Keysight’s Scienlab Dynamic DC Emulator (DCE) series, specifically designed for automotive applications such as emulating batteries and other components for electric vehicles. While the initial product description positions it as a “system local oscillator,” further investigation reveals that the SL1045A is a modular, rack-mounted system designed for power emulation and regenerative testing, operating in a two-quadrant mode as both a power source and a regenerative electronic load. This unit is part of a broader family of test systems for HEV/EV and grid applications.
### Technical Specifications
* **Product Series:** Scienlab Dynamic DC Emulator (DCE) – 48 V Series
* **Product Status:** Discontinued / Currently Supported
* **Primary Function:** Emulation of batteries and other components for automotive applications, particularly in the context of electric vehicle (EV) and hybrid electric vehicle (HEV) testing.
* **Operating Mode:** Two-quadrant operation, functioning as both a power source and a regenerative electronic load.
* **Power Capabilities:**
* Up to 80 V
* Up to ±1200 A
* Up to 44 kW
* **Modular Design:** Rack-mounted system for ease of maintenance and scalability.
* **Regenerative Design:** Eco-friendly design that returns energy to the grid, reducing cooling and electricity costs.
### Electrical Characteristics
* **Voltage Options:**
* 60 V
* 80 V
* **Voltage Source Range:**
* 5 to 60 V
* 5 to 80 V
* **Voltage Sink Range:**
* 5 to 60 V
* 5 to 80 V
* **Current Options:**
* 300 A
* 600 A
* 1200 A
* **Internal Source Parameters (Configurable):**
* Nominal voltage source value (U0) [V]
* Internal voltage source resistance (R0) [Ω]
* Resistance within 1st RC link (R1) [Ω]
* Capacity within 1st RC link (C1) [F]
* Resistance within 2nd RC link (R2) [Ω]
* Capacity within 2nd RC link (C2) [F]
* Internal inductance (L0) [H]
* **Measurement and Acquisition:**
* Analog acquisition of voltage and current using 4-wire measurement.
* Resolution: 32 Bit
* Sample rate: max. 20 kS/s (internal 625 kS/s)
* DC measure and control accuracy are the same.
* **Accuracy:**
* **Voltage Accuracy:** ±0.05 % of measured value, ±16 mV (offset).
* **Current Accuracy:**
* ±0.05 % of measured value, ±60 mA (offset) for 300 A option.
* ±0.05 % of measured value, ±120 mA (offset) for 600 A option.
* ±0.05 % of measured value, ±240 mA (offset) for 1200 A option.
* *Note:* Connecting two systems in parallel does not affect voltage accuracy; the current accuracy offset is multiplied by two, but the percentage error of the measured value remains unaffected.
* **Output Characteristics:**
* **Voltage Ripple:** 300 mVeff typ., 500 mVeff max. at a measuring range of 500 kHz.
* **Voltage Rise Time (10% → 90%):** < 5 ms (typ. 2.5 ms) @ 580 µF load.
* **Voltage Stability:**
* < 12 V @ 48V, 0 → 250A < 1ms, 580 µF.
* < 12 V @ 48V, 0 → 500A < 1ms, 580 µF.
* < 15 V @ 48V, 0 → 1000A < 1ms, 580 µF.### Interfaces and Control* **Control Software:** Can be controlled with Emulator Control software, which is part of the "Machine Emulator" function.
* **Connectivity:** While specific interface details for the SL1045A itself are not extensively detailed, Keysight's broader product lines support various connectivity options including USB, LAN, and GPIB for instrument control and data acquisition.### Physical Characteristics* **System Type:** Modular rack-mounted system.
* **Cooling:** System cooling is integrated.
* **Power Stages:** Employs regenerative power stages.
* **Internal Components:** Features an Active Front End (AFE) and resonance converter.### Compatibility and System Integration* **Application:** Designed for automotive applications, specifically for emulating batteries and other components in HEV/EV and grid testing scenarios.
* **System Integration:** Can be paralleled with other SL1045A units to increase current handling capacity, with specific considerations for accuracy.
* **Related Systems:** Part of a family of solutions that include the Scienlab Charging Discovery System (CDS) and High-Power Series (HP CDS) for comprehensive EV/EVSE charging interface testing.### Documentation* **Data Sheets:** Available for download.
* **Manuals:** Operation and service manuals for Keysight instruments are available, though direct access to the SL1045A specific manual is not explicitly detailed in the search results. Keysight's website and support portal are the primary resources for such documentation.### Legacy Status* **Product Status:** Discontinued, but currently supported. Keysight typically provides ongoing support for discontinued products. No direct replacement product is listed.Why Choose Aumictech for Agilent/Keysight SL1045A?
At Aumictech, we specialize in supplying high-end battery emulation and power testing equipment. Whether you need precise voltage and current control for EV/HEV testing, regenerative load capabilities, or scalable power solutions, our team ensures the Agilent/Keysight SL1045A delivers maximum performance for your application.