The Anritsu MA2400xA series are thermal power sensors engineered for precise average power measurements across RF and microwave frequencies. Built on Seebeck element technology, these sensors deliver true-RMS detection for any incident waveform by measuring thermal gradients and charge migration between dissimilar metals. Each sensor stores calibration factors and linearity correction data in onboard EEPROM, enabling automatic interpolation and correction by compatible power meters.
## Technical Specifications
**Frequency Range**
• MA24002A: 10 MHz to 18 GHz
• MA24004A: 10 MHz to 40 GHz
• MA24005A: 10 MHz to 50 GHz
**Power Measurement**
• Dynamic range: −30 dBm to +20 dBm
• Rise time: < 15 ms
**Sensor Linearity**
• < 1.8% (up to 18 GHz)
• < 2.0% (up to 40 GHz)
• < 2.5% (up to 50 GHz)
• MA24005D specification: −30 to +15 dBm with additional 1% error above +15 dBm
**Standing Wave Ratio (SWR)**
• < 1.90 (10 to 50 MHz)
• < 1.17 (50 to 150 MHz)
• < 1.10 (150 MHz to 2 GHz)
• < 1.15 (2 to 12.4 GHz)
• < 1.20 (12.4 to 18 GHz)
• < 1.25 (18 to 32 GHz)
• < 1.30 (32 to 40 GHz)
• < 1.40 (40 to 50 GHz)
## Key Features
• True-RMS detection delivers accurate average power measurements regardless of signal type
• Precision RF connectors with hexagon coupling nuts for standard torque-wrench attachment
• Internal EEPROM with stored calibration factors and linearity correction algorithms
• Available connector options: N(m), K(m), V(m)
## Typical Applications
• RF and microwave power measurement across DC to millimeter-wave frequencies
• Signal characterization in test and measurement environments
• Power meter integration for automated correction and data logging
## Compatibility & Integration
Designed for use with Anritsu ML2430, ML2480, and ML2490 series power meters. Systems using ML2407A/08A or ML2437A/38A power meters require firmware revision 3.10 or higher when paired with MA24xxD and MA2400xA series sensors.