Anritsu MA2444D Series High Accuracy Diode Sensors (CW) are engineered for consistent and repeatable power measurement across wide frequency ranges. Their rugged design and linear response make them suitable for laboratory and field testing of high-frequency RF components.

Request CalibrationRequest Repair
Product Starting From:

$850.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote MA2444D Series
Equipment info

The Anritsu MA2444D Series High Accuracy Diode Sensors deliver precise CW and TDMA power measurements across 10 MHz to 40 GHz. Built-in 3 dB attenuation minimizes input VSWR, critical for high-gain amplifier characterization. Calibration factors stored in internal EEPROM enable automatic power meter correction. Fast rise time and wide dynamic range support demanding RF and microwave test environments.

## Technical Specifications

**Frequency & Power**
• Frequency range: 10 MHz to 40 GHz
• Dynamic range: −67 dBm to +20 dBm (87 dB span)
• Rise time: <0.004 ms at 0.0 dBm, room temperature
• Sensor linearity: 2.5% below 40 GHz

**Impedance Matching**
• Built-in 3 dB attenuator reduces input VSWR
• SWR performance varies by frequency band:
– 10–50 MHz: <1.90
– 50–150 MHz: <1.17
– 150 MHz–2 GHz: <1.08
– 2–12.4 GHz: <1.16
– 12.4–18 GHz: <1.21
– 18–32 GHz: <1.29
– 32–40 GHz: <1.44

**Connectors & Calibration**
• RF connector: K(m) with hexagon coupling nut for standard torque wrench attachment
• Calibration factors: Stored in internal EEPROM for automatic correction

## Key Features

• 87 dB dynamic range enables measurement from weak to strong signal levels
• Fast 0.004 ms rise time captures transient behavior in TDMA and burst signals
• Frequency-dependent SWR optimization ensures accurate readings across 10 MHz–40 GHz
• Internal EEPROM eliminates manual calibration factor entry

## Typical Applications

• RF amplifier characterization and gain measurement
• TDMA and pulsed power monitoring
• CW power verification in production and field service
• High-frequency component testing to 40 GHz

## Compatibility & Integration

**Power Meters**
• ML2430, ML2480, ML2490 series compatible
• ML2407A/08A and ML2437A/38A meters require firmware revision 3.10 or higher

**Software Support**
• PowerSuite software for ML2430A series—real-time trace viewing and data archiving
• PowerMax™ software for ML2480B and ML2490A series—enhanced visualization and remote control

MPN

MA2444D Series

Frequency Range

10 MHz to 40 GHz

Power Range (dBm)

-67 dBm to +20 dBm

Brand Name