The Boonton 4500A-L is a single-channel RF power meter designed for precision measurement of RF power in various applications. It features a wide dynamic range, high accuracy, and fast measurement speed. Ideal for use in R&D, manufacturing, and service environments.

Request CalibrationRequest Repair
Product Starting From:

$3,400.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 4500A-L
Equipment info

The Boonton 4500A-L is a single-channel RF peak power meter and analyzer designed for precise RF power measurements across a wide frequency range. It offers advanced capabilities for analyzing complex RF signals, making it suitable for research and development, manufacturing, and service environments within the USA. The “-L” designation typically indicates a model equipped with an LCD display, differentiating it from older CRT-based versions.

### Technical Specifications

* **Product Name**: Boonton 4500A-L RF Peak Power Meter
* **Measurement Type**: RF Peak Power Meter and Analyzer
* **Channels**: Single-channel (as indicated by the base model, though some configurations may offer dual-channel options)
* **Frequency Range**: 30 MHz to 40 GHz
* **Dynamic Range**: >60 dB
* **Sampling Rate**: 1 MSa/sec
* **Timebase Resolution**: 100 ps (in some configurations)
* **Accuracy**: Specific accuracy figures are not detailed in the provided search results but are implied by its design for precision measurement.
* **Measurements**:
* Time-domain measurements
* Statistical measurements (CDF, PDF)
* Gated CCDF and PDF with log display (optional)
* 14 automatic measurements
* Dual-channel CDF/PDF capabilities (available in some configurations)
* Power vs. Time Data Output
* Statistical Histogram GPIB Output
* **Triggering**:
* Automatic peak-to-peak, delay-by-time, and delay-by-events triggering
* Flexible triggering
* Triggering options include TTL external trigger level (in some configurations)
* **Display**:
* 8.4-inch TFT color LCD display
* CCFL back-lighted, color VGA LCD display with 640 x 480 pixel resolution
* Waveform display area resolution: 501 x 281 pixels
* Screen saver feature to increase backlight life (for LCD versions)
* **Signal Analysis Capabilities**:
* Analysis of signals with digital modulation, multiple carriers, or complex coding techniques
* Analysis of HDTV and spread-spectrum signals (e.g., CDMA, WCDMA)
* Ability to monitor two sources simultaneously (with dual-channel configurations)
* Powerful math functions for analyzing differences between channels (e.g., output stage compression, intermodulation distortion)

### Electrical

* **Power Source**: Requires connection to a proper power source. The instrument is equipped with a three-conductor, three-prong AC power cable. Verification of the correct fuse for available power is recommended.
* **Calibrator**:
* 1-GHz NIST Traceable Calibrator
* Spectrally pure, 1-GHz NIST traceable calibrator ensures measurement reliability.
* User-selectable automatic routine calibrates the sensor and instrument over the full dynamic range.
* Output: -40 to +20 dBm (CW or pulsed)
* Calibrated power levels from +20 dBm to –40 dBm in steps as small as 0.1 dB.

### Interfaces

* **Data Storage**: PC-compatible 1.44 MB floppy drive for storing data such as front panel setups and trace waveforms.
* **Ports**:
* GPIB
* USB
* LAN
* Parallel printer port
* COM1 serial port (for data buffer output)
* LPT1 line printer port (for data buffer output)
* **Sensor Connection**: Detachable sensor cable (standard 5 feet, with options for 10, 20, 25, and 50 feet).
* **Software**:
* Control software revision 20040521 and later is required for –L versions with LCD displays for correct operation.
* The updated control software is common to all versions.

### Physical

* **Display Type**: LCD color display (for -L versions)
* **Dimensions**: 20 x 16 x 8 inches
* **Weight**: 42 lbs

### Compatibility

* **Sensors**: Compatible with industry-leading 56xxx and 57xxx series peak power sensors.
* **Software**: The –L version requires control software revision 20040521 and later.
* **Previous Models**: Functionally identical to non –L versions, with differences primarily related to the display type. The Model 4500A-L builds upon the capabilities of the Boonton Model 4400A, adding statistical measurements.

Why Choose Aumictech for Boonton 4500A-L?
At Aumictech, we specialize in supplying high-end RF power measurement equipment. Whether you need precision RF power analysis, comprehensive signal characterization, or reliable data acquisition for your R&D or manufacturing processes, our team ensures the Boonton 4500A-L delivers maximum performance for your application.