The Fluke 87V/IMSK Industrial Multimeter Service Combo Kit delivers precision measurement capability for field troubleshooting and bench diagnostics in industrial electrical systems. The kit pairs the Fluke 87V True-RMS digital multimeter with the Fluke i400 AC current clamp, supported by essential accessories including the TL75 test lead set, AC72 alligator clip set, and 80BK-A thermocouple probe.
## Technical Specifications
**Fluke 87V Industrial Multimeter**
• Voltage (DC): 1000 V max, ±(0.05% + 1) accuracy, 10 µV resolution
• Voltage (AC): 1000 V max, ±(0.7% + 2) accuracy at 45–65 Hz, True-RMS with selectable low-pass filter for VFD environments
• Current (DC/AC): 10 A continuous (20 A for 30 seconds), DC accuracy ±(0.2% + 2), AC accuracy ±(1.0% + 2) True-RMS
• Resistance: 50 MΩ max
• Capacitance: 10,000 µF max
• Frequency: 200 kHz max with VFD-compatible filtering
• Duty Cycle: 99.9% max, ±(0.2% per kHz + 0.1%) accuracy
• Conductance: 60.00 nS max
• Temperature: -200.0 to 1090°C (-328.0 to 1994.0°F) with external probe
• Peak Capture: 250 µS response for intermittent fault detection
• Display: 6,000 counts (19,999 in high-resolution mode), analog bar graph, dual-level backlight
• Safety: CAT III 1000 V / CAT IV 600 V, >8000 V spike rated
• Battery: 400 hours typical (backlight off)
• Dimensions: 1.25 × 3.41 × 7.35 in
**Fluke i400 AC Current Clamp**
• Range: 1 A to 400 A AC continuous
## Key Features
• Non-intrusive AC current measurement to 400 A
• True-RMS measurement engine for non-linear signal accuracy
• Selectable low-pass filtering for adjustable-speed drive diagnostics
• Peak capture for transient detection down to 250 µS
• Temperature measurement capability via thermocouple probe
• Audible input alert for jack configuration verification
• High-resolution mode extends display to 19,999 counts
## Typical Applications
• Motor circuit troubleshooting and commissioning
• VFD and variable speed drive diagnosis
• HVAC/refrigeration system service
• Electrical distribution and control panel diagnostics
• Equipment performance validation in industrial plants
## Compatibility & Integration
The 87V multimeter accepts standard banana plugs and supports external thermocouple probes for extended temperature measurement range. The i400 clamp output connects to the millivolts input of compatible multimeters.