The Fluke PM 3370A is a 60 MHz, 2-channel hybrid oscilloscope combining digital storage and analog measurement modes in a single instrument. Designed for electronics troubleshooting, signal analysis, and laboratory testing, it delivers 8-bit vertical resolution with sampling rates up to 20 MS/s per channel (interleaved) or 10 MS/s simultaneous. The autoranging capability automatically optimizes vertical and horizontal scales for clear waveform display across diverse test scenarios.
Technical Specifications
Oscilloscope Performance
• Bandwidth: 60 MHz
• Channels: 2
• Vertical resolution (DSO): 8-bit
• Sampling rate: Up to 20 MS/s per channel (interleaved), 10 MS/s per channel (simultaneous)
• Record length: Up to 1024 points per channel
• Vertical sensitivity: 2 mV/div to 10 V/div (manual ranging)
• Vertical accuracy: ±3% of full scale
• Input impedance: 1 MΩ ±2% || 15 pF ±5 pF
• Maximum input voltage: 400 V (DC + peak AC) CAT II
• Trigger accuracy: ±1 div
• Timebase accuracy: ±0.005% ±50 ppm
• Sweep speed (analog): 0.5 s/div to 50 ns/div
Display
• CRT display, 8 × 10 divisions
• Illuminated internal graticule
• Voltage and time cursors
Power
• Input: 100–240 VAC ±10%, 50/60 Hz
• Consumption: Typically under 50 W
– Key Features
• Dual-mode operation (DSO and analog)
• Input coupling: AC, DC, GND
• Trigger modes: Auto, Normal, Single Shot, Roll Mode
• Trigger types: Edge, Pulse Width, Video, Pattern
• Delayed sweep capability
• Waveform save/recall (DSO mode)
• Built-in self-test diagnostics
• Front panel rotary knobs and function buttons
– Typical Applications
Electronics repair and troubleshooting, real-time signal observation, educational laboratories, waveform analysis, and field service work requiring portable 2-channel measurement capability.
– Compatibility & Integration
Accepts standard passive oscilloscope probes (1×, 10× attenuation). Probe compensation output provided for calibration.