The Keysight/Agilent/HP E1301A is a B-size VXI mainframe with 9 slots—7 external B-size and 2 internal B-size slots plus 3 external A-size slots—designed to integrate VXI instrumentation for automated test equipment and data acquisition systems. The built-in command module provides GPIB (IEEE 488.1) and RS-232 control interfaces, while the front-panel keyboard and two-line vacuum fluorescent display enable local operation and troubleshooting independent of external controllers. Power delivery reaches 120 W maximum at 40°C across multiple rails: +5 Vdc @ 12.2 A, +12 Vdc @ 4.6 A, and -12 Vdc @ 0.9 A. All outputs are protected against over-temperature, over-voltage, over-current, and short-to-ground faults.
Technical Specifications
Chassis and Interfaces
• Form Factor: B-size VXI Mainframe
• Slot Configuration: 9 total (7 external B-size, 2 internal B-size, 3 external A-size)
• Primary Interface: GPIB (IEEE 488.1)
• Secondary Interface: RS-232 at 300, 1200, 2400, 4800, 9600, or 19200 baud
• Command Module: Built-in, functionally identical to HP E1306A
• Front Panel: Keyboard with two-line vacuum fluorescent display
Power Supply
• Output Voltages: +5 Vdc @ 12.2 A, +12 Vdc @ 4.6 A, −12 Vdc @ 0.9 A
• Maximum Usable Power: 120 W at 40°C
• Input: 115 Vac to 230 Vac (50–400 Hz) or optional 11–30 Vdc @ 20 A maximum
• DC switchover time: <5 ms
• Protection: Over-temperature, over-voltage, over-current, short-to-ground; reverse polarity protection on DC input
• VXI Compliance: Generates ACFAIL* and SYSRESET* per VXI Specification Revision 1.4
Thermal and Acoustic
• Temperature Rise: 10 °C typical through module
• Acoustic Noise: <48 dBA at 1 m (per DIN 45635T.1) or <40 dBA
Physical
• Weight: 7.8 kg (17 lbs)
• Dimensions: 426 mm W × 510 mm D × 177 mm H (without feet); 189 mm H (with feet); 569 mm D with terminal blocks
– Key Features
• SCPI and HP IBASIC programming support for standalone or external instrument control
• Integrated resource manager and command module eliminate need for external controller
• Dual-voltage input (AC and optional DC) with transparent switching
• Full VXI backplane signal compliance
• Comprehensive power supply fault protection
– Typical Applications
• Automated test equipment (ATE) systems
• Multi-instrument data acquisition platforms
• Remote or field-based test operations requiring local manual control
– Compatibility & Integration
Accepts standard VXI B-size and A-size modules. Internal 2-slot configuration typically houses multimeter modules such as the E1326A or E1326B.