The Keysight RP7962A is a 10 kW regenerative DC power supply operating at 500 V and ±40 A with bidirectional power flow capability. This two-quadrant system functions simultaneously as a precision power source and electronic load, enabling seamless transitions between sourcing and sinking current without output disruption. The unit accepts three-phase AC input from 400 V to 480 V (±10 %) and recovers 90% of power back to the grid, reducing energy waste and cooling requirements.
Autoranging output expands the voltage-current envelope beyond traditional fixed-ratio supplies, maximizing flexibility across diverse test scenarios. An integrated arbitrary waveform generator produces user-defined transient profiles up to 65,535 data points, while battery emulation mode simulates realistic charge states and internal resistance for high-voltage battery characterization. Programmable output resistance to 50 Ω and continuous current sinking at full rated capacity enable comprehensive power converter and energy storage validation.
Technical Specifications
• Maximum output: 10 kW at 500 V, ±40 A
• AC input: 400–480 VAC, three-phase, ±10 %
• Efficiency: >80%; power factor 0.99
• Output voltage measurement accuracy: 230 mV; programming accuracy: 210 mV
• Noise and ripple: 500 mVpp
• Command processing: Sub-millisecond (1 ms)
• Arbitrary waveform generation: 65,535 data points maximum
• Programmable resistance: Up to 50 Ω
• Form factor: 3U compact (763 × 427 × 132.6 mm, 31.8 kg)
– Key Features
• Two-quadrant operation: Power sourcing and regenerative load modes
• Regeneration efficiency: Returns 90% of power to grid
• Continuous sink capability: 100% rated current indefinitely
• Autoranging output: Extended voltage-current combinations
• Battery emulation: Charge-state and internal-resistance simulation
• Exceptional transient response with fast output speed
• LXI Core, USB 2.0, and GPIB connectivity
– Typical Applications
• Power electronic device validation
• Hybrid and electric vehicle converter testing
• Energy storage system characterization
• DC-DC and AC-DC converter assessment
– Compatibility & Integration
Standard interfaces include LAN (LXI Core), USB 2.0, and GPIB for integration into automated test systems.