The Lambda/TDK EMI ESS60-165-7-D is a programmable DC power supply delivering 10 kW to 15 kW of regulated power in a 5U rack-mount form factor. It operates in both constant voltage and constant current modes with pulse-by-pulse current limiting, making it suitable for high-current applications including RF amplifiers, DC motors, and magnetic coils. The unit features integral cooling, analog front-panel control via ten-turn potentiometers, and optional remote programming through RS232/IEEE 488 interfaces. Line and load regulation both hold better than 0.1% across full load changes. Output stability maintains ±0.05% deviation over 8-hour periods under constant operating conditions.
## Technical Specifications
• Output Power: 10 kW or 15 kW (model dependent)
• Output Voltage: Up to 600 V (500 V at 15 kW)
• Output Current: Up to 1400 A
• Ripple & Noise: 50–300 mV peak-to-peak (model dependent)
• Line Regulation (CV/CC modes): <0.1%
• Load Regulation (CV/CC modes): <0.1% for 0–100% load change
• Transient Response: <650 µs for 30% load step (≤20 VDC models)
• Efficiency: 85–91% (model dependent)
• Output Voltage Stability: ±0.05% over 8 hours at constant line, load, and temperature
• Temperature Coefficient (Voltage): 0.02% per °C
• Temperature Coefficient (Current): 0.03% per °C
• Input: Three-phase, 190–250 VAC / 380–460 VAC / 400–480 VAC, 47–63 Hz
• Power Factor: 0.9
• Cooling: Integral fan
• Warranty: 5 years
## Key Features
• Ten-turn voltage and current potentiometers with analog or digital metering
• Pulse-by-pulse current limiting for transient protection
• LED status indicators: Overvoltage, Inverter Failure, Phase Loss, Control Failure
• UL-listed primary circuit breaker
• Optional RSTL controller board for 0–5 V analog programming and digital interface
• Established since 1995 for laboratory and OEM environments
## Typical Applications
RF amplifier testing, DC motor control, magnetic coil excitation, and high-current component characterization.
## Compatibility & Integration
Front-panel analog control is standard. Remote operation requires optional RS232/IEEE 488 interface card. Three-phase input configuration varies by model and regional voltage standard.