The Lambda / TDK / EMI ESS60-165 is a power supply unit designed for various electronic applications. It provides a stable and reliable power source with specific voltage and current ratings. This power supply is suitable for use in industrial, commercial, and laboratory settings.

Request CalibrationRequest Repair
Product Starting From:

$2,950.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote ESS60-165
Equipment info

The Lambda/TDK/EMI ESS60-165 is a 15 kW programmable DC power supply delivering 0–60 VDC at 0–165 ADC for high-current industrial and laboratory applications. It combines constant voltage and constant current operation with automatic crossover, pulse-by-pulse current limiting, and front-panel adjustment via 10-turn potentiometers or optional RS232/IEEE 488 interfaces. Output stability is exceptional: line regulation better than 0.1%, load regulation under 0.1%, and 8-hour drift under 0.05% at constant conditions.

## Technical Specifications

**Power and Output**
• Rated power: 15,000 W
• Output voltage: 0–60 VDC
• Output current: 0–165 ADC
• Ripple: 75 mV RMS (5 Hz–1 MHz)
• Efficiency: 85% at 100/200 VAC input
• Power factor: 0.9 (passive)

**Regulation and Stability**
• Line regulation (CV/CC): <0.1% across full AC input range
• Load regulation (CV): <0.1% for 100% load change
• Load regulation (CC): <0.1% for 100% load change
• Stability (8-hour): <0.05% under constant conditions
• Transient response: <650 µs for 30% load step (≤20 V); Vmax/20 above 20 V
• Temperature coefficient: 0.02% per °C (voltage); 0.03% per °C (current)

**Environmental**
• Operating temperature: 0°C to 50°C continuous; derates 4% per °C above 50°C
• Storage temperature: −55°C to 85°C

## Key Features

• Automatic CV/CC crossover with mode indication
• Adjustable overvoltage protection (OVP)
• Failsafe soft start
• Series or parallel operation capability
• Front-panel dual meters (voltage and current simultaneous display)
• Optional remote control interfaces
• ISO 9001 certified manufacturing
• Five-year warranty

## Typical Applications

• RF amplifier testing
• DC motor and magnetic coil drive
• High-current load simulation
• OEM and bench-top laboratory use

## Compatibility & Integration

**Input Options**
• 100–200 VAC, 3-phase
• 190–250 VAC, 3-phase
• 400 VAC, 3-phase, 30 A, 47/63 Hz
• Higher voltages (380 VAC+) require 5-wire configuration; conversion transformers available

**Legacy Status**: This model is not recommended for new designs. Genesys™ and GENESYS+™ series are recommended alternatives.