The LeCroy WaveJet 352 is a 500 MHz, 2-channel digital oscilloscope built for signal analysis, debugging, and characterization across bench and field environments. It delivers 2 GS/s interleaved sampling (1 GS/s all channels) with 500 kpts/channel memory, enabling capture of complex waveforms with both fast and slow components. The 7.5-inch color TFT-LCD display (640 × 480 VGA) provides clear real-time visualization of measurements and waveform detail.
Technical Specifications
Vertical Performance
• Bandwidth: 500 MHz with 750 ps rise time
• Vertical sensitivity: 2 mV/div to 10 V/div (1 MΩ); 2 mV/div to 2 V/div (50 Ω)
• Vertical resolution: 8-bit
• DC gain accuracy: ±(1.5% + 0.5% of full scale)
• Input impedance: 1 MΩ ±1.5% || 20 pF; 50 Ω ±1.5%
• Input coupling: GND, DC 1 MΩ, AC 1 MΩ, or DC 50 Ω
• Bandwidth limiting filters: 20 MHz, 200 MHz
Horizontal Performance
• Sampling rate (single-shot): 2 GS/s interleaved, 1 GS/s all channels
• Sampling rate (RIS): 100 GS/s
• Memory: 500 kpts/channel
• Timebase range: 500 ps/div to 50 s/div
• Timebase accuracy: 10 ppm (typical)
• Peak detect period: 1 ns
Triggering & Control
• Trigger modes: Auto, Normal, Single, Stop
• Trigger types: Edge, Glitch, Period, Pulse Width, Pulse Count, TV
• Trigger sources: Any channel, Ext, Ext/10, Line
• Trigger coupling: AC, DC, LFRej, HFRej
• Holdoff: up to 50 seconds
– Key Features
• Maximum input: 400 V CAT I (1 MΩ); 5 Vrms (50 Ω)
• BNC probing with Probe Sense Ring; PP006A probes included
• Capture time: 500 µs @ 1 GS/s, 250 µs @ 2 GS/s
• Roll mode: 50 ms/div to 50 s/div (100 kS/s maximum)
– Compatibility & Integration
• USB 1.1 port: Screen images and waveform data storage
• GPIB and Ethernet: Remote control and data transfer
• Compact form factor: 4-inch depth for portable and space-constrained installations