Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Marconi IFR Aeroflex 1200SUPER-S Communications Service Monitor

SKU: 1200SUPER-SCategories: RF Transceivers & Test Sets
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

The Marconi IFR Aeroflex 1200SUPER-S Communications Service Monitor is a comprehensive test instrument for analyzing and maintaining communication systems. It integrates various functions, including a signal generator, spectrum analyzer, oscilloscope, and power meter, into a single unit. Ideal for testing mobile radios, pagers, and other wireless communication devices, it offers features like automated test sequences and detailed signal analysis, ensuring accurate and efficient system performance verification.

Request CalibrationRequest Repair
Product Starting From:

$2,479.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 1200SUPER-S
Equipment info

The Marconi IFR Aeroflex 1200SUPER-S is a microprocessor-controlled, digitally synthesized communications service monitor integrating RF signal generation, reception, and analysis into a portable platform. Purpose-built for testing mobile telephone systems, AM/FM/SSB transceivers, CB and two-way radio systems, and repeaters, it delivers multiple measurement functions via analog meter and VFD display. The Super S variant includes battery operation (12 to 30 VDC) and tracking generator capability, enabling field deployment without AC mains dependency.

Technical Specifications

RF Signal Generator
• Frequency range: 250 kHz to 999.9999 MHz
• Frequency resolution: 100 Hz
• Output range: -127 to -20 dBm
• Output resolution: 10 dB steps with 11 dB vernier
• Accuracy: 2.5 dB (3.0 dB at -20 dB attenuator setting)
• Modulation: FM, AM
• Spectral purity (harmonics): -30 dBc
• Spectral purity (non-harmonics): -55 dBc

Duplex Generator
• Frequency offset range: 0 to ±49.9975 MHz from receive frequency
• Frequency resolution: 2.5 kHz
• Output levels: -40 dBm (Low), -15 dBm (High) into 50 Ω

Receiver
• Frequency range: 250 kHz to 999.9999 MHz
• Sensitivity: 2 µV (triple conversion)
• Supported modulation: AM, FM, SSB
• Antenna input protection: 0.25 W

Spectrum Analyzer & Oscilloscope
• Analyzer frequency range: 250 kHz to 1 GHz, 70 dB dynamic range
• Oscilloscope bandwidth: 1 MHz

Physical & Power
• Dimensions: 332 mm (W) × 185 mm (H) × 445 mm (D)
• Weight: 17.2 kg without options
• Power input: 105–130 VAC or 210–260 VAC (50–400 Hz); or 12–30 VDC
• Power consumption: 60 W typical

– Key Features

• Integrated RF power meter, frequency error meter, audio frequency error meter
• CTCSS frequency and modulation meter; FM deviation meter; AM modulation meter
• Distortion and SINAD measurement capabilities
• Support for DCS, DTMF, pulsed audio, and paging signaling formats (DCS, DTMF, MTS, IMTS)
• CLEARCHANNEL LTR® trunking option for LTR mobile, portable, and repeater testing
• Optional high-stability time base: 0.05 ppm OCXO
• Tracking generator for SWR Return Bridge accessory use

– Typical Applications

• Mobile telephone system commissioning and maintenance
• Two-way radio system field service
• Repeater performance verification
• CB and amateur radio transceiver testing

– Compatibility & Integration

• RS-232 port standard for remote control and data logging
• IEEE-488 (GPIB) interface option available as RS-232 replacement

MPN

1200SUPER-S

Frequency Range

250 kHz to 999.9999 MHz (RF generator and receiver); 250 kHz to 1 GHz (spectrum analyzer)

Power Range (dBm)

-127 to -20 dBm (RF generator output); -40 dBm to -15 dBm (duplex generator)

Voltage / Current Range

105–130 VAC or 210–260 VAC (50–400 Hz); 12–30 VDC

Brand Name

Marconi / IFR / Aeroflex

You May Also Like