The N2Power XL125-1 is a 125-watt quad output AC-DC power supply engineered for high-density applications requiring compact form factors and high efficiency. This ultra-small unit delivers a 3″ × 5″ footprint at 1.25″ height, making it ideal for 1U chassis integration. With universal AC input (85–264 VAC) and optional DC-DC input capability (120–370 VDC), the XL125-1 achieves up to 92% power conversion efficiency through active Power Factor Correction technology, minimizing energy loss and thermal output. The quad output configuration provides flexible voltage rails—typical outputs include 3.3V @ 10A, 5V @ 15A, 12V @ 5A, and -12V @ 1A—to supply diverse subsystem loads. All outputs include overvoltage, short circuit, and overpower protection, with integrated thermal shutdown safeguarding against over-temperature conditions. Remote sense capability enables precision voltage regulation, while Power Good signaling (PS_OK) supports system monitoring. Optional current sharing supports parallel operation via OR-ing diode or MOSFET configurations.
Technical Specifications
• Input voltage: 85–264 VAC (universal AC) or 120–370 VDC (DC-DC)
• Total output: 125 watts
• Output configuration: Quad outputs (3.3V/10A, 5V/15A, 12V/5A, -12V/1A example)
• Power conversion efficiency: Up to 92%
• Standby power consumption: ~0.3 W
• Output ripple and noise: 50 mV @ 3.3V, 120 mV @ 12V
• Operating temperature: -25°C to +50°C
• Storage temperature: -40°C to +85°C
• Temperature derating: 2.5% per degree C to 70°C
• Forced air cooling requirement: 5 CFM recommended
• Power density: 6.7 watts per cubic inch
– Key Features
• Active Power Factor Correction reduces energy consumption and heat generation
• Integrated protection: overvoltage, short circuit, overpower, and thermal shutdown
• Remote sense and Power Good monitoring outputs
• Optional current sharing for parallel configurations
• Compact 1U-compatible form factor
– Compatibility & Integration
Connector interfaces include AC input (J1), DC output (J2), remote sense/Power Good (J3), and single output mode (J4). Safety ground connection via plated through hole. UL 60950-1:2007 and CSA C22.2 No. 60950-1-07 certified; FCC Part 15 Subpart B and EU Low Voltage Directive 2006/95/EC compliant.