The NoiseCom UFX series is a line of precision broadband noise generators engineered to deliver white Gaussian noise across wide frequency spectra for signal jamming, testing, and calibration applications. Microprocessor-controlled instruments, UFX models combine compact design with stable performance and operate via front-panel controls or remote IEEE-488 (GPIB) command. Selectable frequency ranges span 10 Hz to 4 GHz across the product line, with output power up to +30 dBm and attenuation control from 0 to 127 dB in 1 dB steps (0.1 dB optional). A true RMS power meter accurately measures Gaussian noise signals with crest factors to 18 dB across a −55 dBm to +5 dBm range.
Technical Specifications
• Noise output: White Gaussian noise
• Frequency ranges: 10 Hz–20 kHz, 10 Hz–500 kHz, 10 Hz–10 MHz, 100 Hz–100 MHz, 100 Hz–500 MHz, 100 Hz–1 GHz, 100 Hz–1.5 GHz, 1 GHz–2 GHz, 1 MHz–2 GHz, 2 GHz–4 GHz, and model-specific ranges
• Output power: Up to +30 dBm (model dependent)
• Noise density: −27 dBm/Hz (model specific)
• Output flatness: ±2 dB (model specific)
• Attenuation: 0 to 127 dB in 1 dB steps; optional 0.1 dB steps; units >2 GHz: 0 to 79 dB or 79.9 dB total
• Attenuator accuracy: ±0.2 dB or 0.5% (1–500 MHz); ±0.2 dB or 1% (0.5–1.0 GHz); ±0.3 dB or 2% (1–2 GHz)
• Power meter range: −55 dBm to +5 dBm
• Input power: 120 VAC 60 Hz; optional 230 VAC 50 Hz; UFX-BER: 85–264 VAC 47–63 Hz 2 A max
• Warm-up time: 30 minutes
– Key Features
• True RMS power meter with Gaussian noise crest factor measurement to 18 dB
• Interferer input: −4 dBm ± 2 dB
• SMA female output connector (K female for UFX7240; optional N or BNC)
• Dimensions: 17 in. × 5.25 in. × 12.5 in. deep
– Compatibility & Integration
• Local control via front-panel keypad
• IEEE-488 (GPIB) bus interface
• Optional Ethernet TCP/IP, RS-232, RS-422, and RS-423 interfaces