The North Atlantic 5410C-89-1 is a C-size VXIbus module delivering bidirectional synchro/resolver conversion in a single instrument. It integrates three synchro/resolver to digital (S/D) channels for angle measurement and three digital to synchro/resolver (D/S) channels for signal stimulus, addressing measurement and simulation tasks in a unified platform.
Technical Specifications
Synchro/Resolver to Digital Channels
• 3 measurement channels with transformer isolation
• Input voltage: 3.5 V to 100 V line-to-line (autoranging); optional 2 V to 26 V
• Reference voltage: 5 V to 115 Vrms (autoranging)
• Reference frequency: 360 Hz to 5 kHz
• Resolution: 0.001°
• Accuracy (no load): 0.0083°
• Accuracy (loaded, 400 Hz / 2800 Hz / 5000 Hz): ±0.010°
• Tracking speed: 180°/sec maximum
• Input impedance: 100 kΩ minimum
• Auto phase current: ±60°
• Settling time: 2 seconds
Digital to Synchro/Resolver Channels
• 3 output channels with transformer isolation
• Output format: Single or two-speed programmable
• Reference voltage: 5 V to 115 Vrms (autoranging)
• Reference frequency: 360 Hz to 5 kHz
• Resolution: 16 bits
• Accuracy (no load): 0.0055°
• Accuracy (loaded): ±0.0055° to ±0.0275° depending on frequency band (360 Hz–7.5 kHz)
• Programmable rotation: 0.1°/sec to 1000°/sec with 0.1°/sec resolution
• Stepping rate: 0.02° increments
• Current drive: 3.0 mA maximum total
• Output protection: Short circuit protected
Interface & Performance
• Message-based Control Intermediate Interface Language (CIIL)
• VXIbus data rate: 500 Kbytes/sec
• Processor conversion time: 5 ms
• Data formats: Floating point, decimal, integer, string, scientific
• Triggering: External or internal
• Self-test: Wrap-around mode included with 95% fault detection to module level within 1 minute
– Key Features
• Transformer-isolated input and output channels reduce noise coupling
• Autoranging measurement accommodates wide voltage and reference ranges without manual reconfiguration
• Programmable output voltage scales directly with reference voltage
• Programmable rotation and stepping enable dynamic angle simulation without external controllers
– Typical Applications
Aircraft navigation system testing, inertial measurement unit calibration, synchro motor control verification, resolver signal validation, and angular position feedback simulation in aerospace and defense test environments.
– Compatibility & Integration
VXIbus C-size form factor integrates into standard VXI mainframes. CIIL control supports message-based programming across networked test systems.