The Rohde & Schwarz URV5 (394.8010.02) is a precision RF voltmeter for broadband voltage, level, and power measurements spanning DC to 26.5 GHz. It delivers ±1% basic accuracy through microprocessor-controlled error correction and maintains a dynamic range exceeding 94 dB. The instrument accommodates two test inputs and supports modular probe and sensor configurations, making it suitable for both standalone operation and automated test system integration.
Technical Specifications
Measurement Ranges
• Voltage: 200 µV to 1000 V (DC to 26.5 GHz, probe/sensor dependent)
• Level: −40 dBm to +53 dBm (with URV5-Z2 or URV5-Z4 insertion units, 100 kHz to 3 GHz)
• Power: 100 nW to 200 W (+53 dBm maximum, using compatible power sensors)
• Frequency: DC, 9 kHz to 26.5 GHz (varies by accessory; insertion units operate 100 kHz to 3 GHz)
Accuracy & Performance
• Basic Accuracy: ±1% (microprocessor error correction)
• Dynamic Range: >94 dB
• Measurement Rate: Up to 30 measurements/second with adjustable filtering (FO to F5)
• Waveform Response: RMS weighting for sine waves; peak measurement for non-sinusoidal signals above specified thresholds
• Frequency Response: Individually calibrated measuring head compensation
RF Probe Specifications (URV5-Z7)
• Voltage Range: 200 µV to 10 V (DC to 1 GHz); extendable to 1000 V with plug-on dividers
– Key Features
• Dual test inputs for flexible measurement configuration
• Interchangeable probes, insertion units, and power sensors—all individually calibrated
• Measuring heads with integrated calibration data and temperature sensors
• Selectable reference impedance
• Relative measurement modes: difference (ΔV), percentage difference (Δ%), logarithmic difference (ΔdB), and ratio (X/REF)
• Peak envelope power (PEP) measurement: minimum pulse width 200 µs, down to 0.05 Hz repetition frequency
• Fast tendency indication for real-time adjustment guidance
• Display output in standard units
– Typical Applications
RF power and voltage characterization; broadband signal level measurement; modulated signal envelope analysis; multi-point test automation; frequency-dependent network and component evaluation.
– Compatibility & Integration
IEC/IEEE Bus interface enables direct integration into automated test systems. Compatible with URV5-Z2 and URV5-Z4 insertion units, URV5-Z7 RF probe, and NRV-Z series power sensors.