Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Service & Repair of Ericsson FSU 995FA Fusion Splicer

SKU: 995FACategories: Fusion Splicer Repair
Brand: Ericsson
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

Professional service and repair for Ericsson FSU 995FA Fusion Splicers, ensuring optimal performance and reliability for your fiber optic splicing needs.

Request CalibrationRequest Repair
Product Starting From:

$100.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 995FA
Equipment info

Ericsson FSU 975FA & 995FA Fusion Splicer – Expert Repair, Precision Alignment & Arc Calibration

We provide professional repair, maintenance, and calibration services for the Ericsson FSU 975FA and 995FA Fusion Splicers—core alignment fusion splicers trusted worldwide for high-precision optical fiber splicing. These fully automatic (FA) models are known for their speed, accuracy, and repeatable low-loss splices, making them ideal for high-volume telecom deployments, fiber network maintenance, and lab environments. If your splicer is failing to align, showing splice loss errors, or experiencing arc issues, our expert technicians are equipped to restore it to full operational condition with OEM-level accuracy.


Our Fusion Splicer Repair Process

Comprehensive Evaluation & Testing
Each Ericsson FSU 975FA or 995FA unit is inspected and tested in detail to evaluate:

  • Arc power stability and arc count calibration

  • Fiber alignment (X/Y/Z axes) and core detection performance

  • Splice loss estimation accuracy and repeatability

  • Condition of V-grooves, fiber clamps, and electrodes

  • Motor responsiveness and alignment travel range

  • Battery health and charge cycle status

  • Display screen clarity and interface responsiveness

  • Communication ports and internal software stability

We test both single-mode and multimode fibers, under simulated field conditions, to identify real-world issues during splice cycles.

Common Issues We Repair

  • High splice loss or alignment failure

  • No arc or irregular arc discharge

  • Misalignment or sluggish X/Y motor movement

  • Worn or misaligned electrodes

  • Dirty, cracked, or misaligned V-grooves and fiber holders

  • Boot-up errors or frozen interface

  • LCD/display screen dimming or failure

  • Keypad or button malfunctions

  • Battery not charging or unit shutting off unexpectedly

  • Internal software glitches or firmware mismatch

Precision Mechanical Repair & Cleaning
We restore mechanical components with care, including:

  • Electrode cleaning or replacement

  • V-groove cleaning, realignment, and tension adjustment

  • Fiber holder and clamp inspection and reconditioning

  • Full disassembly and cleaning of internal optics and lenses

Motor & Axis Calibration
All internal motors (X, Y, Z) are tested and calibrated for precision movement and core alignment. We measure travel accuracy, backlash, and positioning, replacing faulty motors or sensors as needed.

Display & Control Interface Repair
Display screens, control panels, and keypads are inspected, repaired, or replaced to ensure a fully functional user interface and splicing workflow.

Firmware, Settings & Functional Verification
Units are reset, updated (if applicable), and run through full diagnostics:

  • Arc test

  • Loss estimation

  • Splice simulation

  • Heating cycle (if heater is integrated)

NIST-Traceable Calibration & Splice Testing
After repairs, we conduct NIST-traceable calibration, including:

  • Arc calibration tailored to fiber type

  • Alignment repeatability testing

  • Splice loss and signal integrity checks using industry test fibers

  • Environmental and thermal stability tests
    We provide a performance report and calibration certificate with before-and-after data.


Why Choose Us?

  • Deep expertise in Ericsson FSU fusion splicers, including fully automatic 975FA and 995FA models

  • Real-world testing methods simulating actual fiber deployment conditions

  • Fast service turnaround – typically within 3–5 business days

  • Warranty on all repairs and a 15-day Right of Return

  • Professional packaging and international shipping available

  • Secure payments via credit card, PayPal, ACH, or wire transfer


Best For:

  • Fiber installation crews requiring low-loss splicing performance

  • Telecom companies extending the life of high-precision Ericsson equipment

  • Resellers needing fully restored and certified FA-series units

  • Field service teams relying on fully automatic, fast-splice systems


Restore Splice Precision & Reliability to Your Ericsson FSU 975FA or 995FA

If your Ericsson FSU 975FA or 995FA Fusion Splicer is misaligning fibers, failing arc tests, or displaying system errors, our technicians can fully restore its performance. With certified repair procedures, high-end calibration equipment, and years of optical splicing experience, we bring your splicer back to field-ready condition—accurate, consistent, and dependable.

Request a quote today and let us return your fusion splicer to peak performance.

MPN

995FA

You May Also Like

Can't Find The Right Product? Contact Us.