The Teledyne LeCroy CP030-3M is an AC/DC current probe that measures continuous currents up to 30 A RMS and peak currents to 50 A with a 10 MHz bandwidth. This non-invasive probe uses Hall effect and transformer technology to acquire current waveforms without breaking circuits or inserting shunts, accommodating conductors up to 5 mm diameter. The 3 meter cable connects via ProBus directly to compatible Teledyne LeCroy oscilloscopes, eliminating the need for external power supplies or signal conditioning.
Technical Specifications
• Maximum Continuous Current (RMS): 30 A
• Maximum Peak Current: 50 A
• Bandwidth: 10 MHz
• Rise Time (Typical): ≤35 ns
• Output Voltage: 0.1 V/A
• Sensitivity: 10 mA/div, 1 mA/div
• Maximum DC Input Current (0.1 V/A sensitivity): 30 A
• Maximum DC Input Current (1 V/A sensitivity): 5 A
• Conductor Size: Up to 5 mm diameter
• Cable Length: 3 meters
• Safety Category: CAT I, 300 V
– Key Features
• Hybrid Hall effect and transformer technology for AC, DC, and impulse current measurements
• Non-invasive clamping design—no circuit interruption required
• Small form factor enables access to congested board layouts
• ProBus-powered integration with full oscilloscope control
• Automatic current waveform scaling displayed in Amps
• Automatic power calculation with Watts scaling
• Degauss cycle: ~5 seconds, triggered via Auto Zero
• User-accessible Degauss and Auto Zero functions from oscilloscope interface
• No external hardware or auxiliary power supplies needed
– Typical Applications
AC/DC current acquisition in power electronics, switch-mode power supplies, motor drives, and signal integrity analysis where non-invasive measurement is required.
– Compatibility & Integration
Works with Teledyne LeCroy MAUI oscilloscopes with ProBus interface running Windows XP Professional or later; X-Stream firmware 7.8.x.x or later for CP03xA models. Also compatible with WaveSurfer 3000z/4000HD, WavePro, WaveRunner/WaveMaster 8000HD, HDO4000A/6000B, and MDA 8000HD.