The Teledyne LeCroy CP500 is a Hall-effect and transformer-based current probe for AC, DC, and impulse current measurements up to 500 A RMS with 2 MHz bandwidth. Its split-core design clamps onto conductors without circuit interruption, accommodating conductors up to 20 mm diameter. The probe connects via ProBus active interface to Teledyne LeCroy oscilloscopes, delivering integrated power and enabling automatic waveform scaling in Amps, calculated power traces in Watts, and oscilloscope-controlled Degauss and Autozero functions.
Technical Specifications
• Maximum Continuous Current: 500 A RMS
• Peak Pulse Current: 700 A
• Bandwidth: 2 MHz (switchable to 20 MHz via CP500 dialog)
• Minimum Measurable Current: 100 mA
• Sensitivity: 100 mA/div
• Input Coupling: AC/DC
• Maximum Input Voltage: 600 V
• Safety Rating: CAT II 600V, CAT III 300V
• Cable Length: 6 meters
• Maximum Conductor Size: 20 mm
– Key Features
• Split-core clamp design for non-invasive installation
• Hybrid Hall-effect and transformer technology for low-noise DC, AC, and transient current measurement
• ProBus active probe interface eliminates external power supplies and amplifiers
• Automatic current scaling and computed power calculations in the oscilloscope display
• Integrated Degauss and Autozero control via oscilloscope interface
– Typical Applications
Designed for characterization and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies where accurate current analysis is critical.
– Compatibility & Integration
Compatible with Teledyne LeCroy WaveRunner, WavePro, and LC series oscilloscopes with firmware 4.3.0.0 or higher. ProBus interface provides direct integration with compatible oscilloscopes. Third-party current transducer integration available via CA10 Programmable ProBus Current Sensor Adapter. Supports deskew calibration with DCS025 calibration source.