The Teledyne LeCroy T3CP150-12 is an AC/DC current probe designed for accurate current measurements up to 150 A with a bandwidth of 12 MHz. It allows users to measure both AC and DC currents without breaking the circuit, making it suitable for power electronics, motor drives, and automotive applications. The probe features a compact design and easy-to-use interface, ensuring reliable and precise current measurements.

Request CalibrationRequest Repair
Product Starting From:

$4,229.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote T3CP150-12
Equipment info

The Teledyne LeCroy T3CP150-12 is an AC/DC current probe delivering precise, non-invasive current measurements up to 150 A RMS with 12 MHz bandwidth. Engineered for power electronics, motor drives, and electric vehicle testing, this dual-range probe combines DC and AC measurement capability with selectable sensitivity (30 A and 150 A ranges) to capture both transient detail and steady-state behavior. The probe integrates dual-indicator over-current protection (audible buzzer and LED alert), automatic zero setting, and degaussing functions to maintain measurement integrity across extended test sessions. A compact probe head (176 × 39.5 × 18 mm) accommodates conductors up to 5 mm diameter, while the control box supplies range selection and user-initiated calibration controls. Connected via 1 m cable to the control unit, the T3CP150-12 interfaces with oscilloscopes through standard BNC high-impedance input.

Technical Specifications

• Bandwidth: DC to 12 MHz (−3 dB)
• Continuous Maximum Current: 150 A RMS
• Peak Input (≤10 µs): 300 A
• Measurement Ranges: 30 A and 150 A
• Current Transfer Ratio:
– 30 A range: 1 V/A
– 150 A range: 0.01 V/A
• Minimum Measurable Current:
– 30 A range: 5 mA
– 150 A range: 50 mA
• Amplitude Accuracy (DC, 45–66 Hz):
– 30 A range: ±1%, ±10 mA
– 150 A range: ±1%, ±100 mA
• Risetime: ≤29 ns
• Maximum Conductor Diameter: 5 mm
• Power Input: DC 12 V / 1 A (universal external supply)
• Operating Temperature: 0 to 40°C
• Operating Humidity: ≤80%

– Key Features

• Dual-range sensitivity for flexible current measurement across different circuit conditions
• Simultaneous DC and AC measurement capability
• Audible and visual over-current protection indicators
• Degaussing and automatic zero setting for sustained accuracy
• Low-current measurement resolution down to 5 mA on 30 A range

– Typical Applications

Power electronics characterization, motor drive analysis, electric vehicle battery and drivetrain testing, switching converter evaluation, and current distribution measurement in multi-phase systems.

– Compatibility & Integration

BNC connector interface; designed for oscilloscopes with high-impedance BNC input. Probe head to control box connection via 1 m cable; total system cable length 1.5 m. Control box dimensions: 91.44 × 39.87 × 26.41 mm. System weight: 235 g.

MPN

T3CP150-12

Frequency Range

DC to 12 MHz

Voltage / Current Range

30 A to 150 A RMS (peak 300 A)

Brand Name

Teledyne LeCroy