The Agilent/Keysight 6235A is a triple-output DC power supply engineered for benchtop development and testing of linear and digital integrated circuits. It delivers constant-voltage, current-limited operation across three independent outputs with configurable tracking and series capabilities. The 6235A combines a 0V to +6V output (1A max) with two ±18V tracking outputs (0.2A each), or alternatively stacks the ±18V channels in series for 0V to 36V at 0.2A.
Technical Specifications
Output Configuration
• Output 1: 0V to +6V at 0–1A (6W max)
• Output 2: 0V to +18V at 0–0.2A (3.6W max)
• Output 3: 0V to −18V at 0–0.2A (3.6W max)
• Series Mode: 0V to 36V at 0.2A (Outputs 2 and 3 combined)
Electrical Performance
• Ripple and noise: <1 mV RMS, <5 mV peak-to-peak (20 Hz to 20 MHz) across all outputs
• Load transient recovery: <50 µs to within 15 mV of nominal following half/full load transitions
• Line regulation: <0.1% + 10 mV (dc to 20 Hz) over 8 hours
• Load regulation: <0.1% + 10 mV (dc to 20 Hz) over 8 hours
• Short-circuit protection: Auto-limiting at 1.275A ±15% (0V to +6V output); 0.255A ±15% (±18V outputs)
Power Input
• 104–127 VAC, 47–63 Hz, single-phase (standard)
• 240 VAC line voltage option available
• Maximum input: 35 VA
Physical & Environmental
• Form factor: Benchtop; compact, impact-resistant stackable case
• Operating temperature: 0°C to +40°C ambient
• Humidity: Maximum 95% relative humidity
• Altitude: Up to 2000 meters
• Connections: Front-panel binding posts; isolated common output terminal; rear chassis ground
– Key Features
• Tracking ±18V outputs for dual-rail supply applications
• Independently adjustable channels with individual current limiting
• Series/parallel/tracking auto-configuration modes
• Short-circuit proof design
• Fast transient response under dynamic loading
• Low noise suitable for sensitive analog circuits
– Typical Applications
Developmental and laboratory testing of discrete and integrated circuits; dual-rail analog circuit prototyping; single-rail supplies up to 36V via series connection.
– Compatibility & Integration
Front-panel binding posts provide direct connection to standard banana plugs and test leads. Common output isolation from chassis ground enables flexible ground referencing schemes.