The Agilent/Keysight 8562A is a portable spectrum analyzer delivering synthesized tuning for drift-free accuracy across 1 kHz to 22 GHz, with optional extension to 26.5 GHz or 325 GHz via external mixers. Purpose-built for RF and microwave measurement in field environments, it combines military-specification ruggedization with comprehensive signal analysis capabilities. The instrument provides resolution bandwidth from 100 Hz to 2 MHz, video bandwidth to 3 MHz, and AM/FM demodulation. Its -120 dBm displayed average noise level (1 MHz to 2.9 GHz) and 118 dB dynamic range enable detection and characterization of weak signals across multiple frequency bands. Input protection handles +30 dBm average continuous power and +50 dBm peak pulse power, with rigid mechanical design withstanding 30 g shock and MIL-T-28800C transit specifications.
Technical Specifications
Frequency & Resolution
• Frequency range: 1 kHz to 22 GHz (Option 026: to 26.5 GHz; external mixers: to 325 GHz)
• Resolution bandwidth: 100 Hz to 2 MHz (1, 3, 10 sequence plus 2 MHz)
• Video bandwidth: 1 Hz to 3 MHz
• Counter resolution: 10 Hz to 1 MHz (selectable)
• Frequency accuracy: 150 Hz at 1 GHz (with optional precision reference)
Amplitude & Dynamic Range
• Reference level: -120 dBm to +30 dBm in 0.1 dB steps
• Displayed average noise level: -120 dBm (1–2.9 GHz), -121 dBm (2.75–6.46 GHz), -110 dBm (5.86–13.0 GHz), -105 dBm (12.4–19.7 GHz), -100 dBm (19.1–22.0 GHz)
• Maximum dynamic range: 118 dB
• Maximum safe input: +30 dBm average continuous (1 W, ≥10 dB attenuation); +50 dBm peak pulse (100 W, ≥30 dB attenuation, <10 µs pulse, <1% duty cycle)
Demodulation & Interfaces
• AM and FM demodulation
• Front panel: Type N RF input (50 Ω), SMA second IF input, SMA first LO output, BNC calibrator
• Rear panel: BNC 10 MHz reference (input/output), BNC video output, BNC LO sweep/0.5 V per GHz, BNC external trigger, HP-IB interface
Physical & Environmental
• Operating temperature: -10°C to +55°C
• Warm-up: 5 minutes
• Dimensions: 163 mm H × 325 mm W × 427 mm D
• Weight: 20 kg (44 lbs)
• Ruggedization: MIL-T-28800C (temperature, pulse shock, transit drop); 30 g shock withstand
Power
• AC: 47–440 Hz, 115 VAC (90–140 V RMS, 3.2 A max) or 230 VAC (180–250 V RMS, 1.8 A max)
– Key Features
• Synthesized local oscillator eliminates frequency drift
• Frequency response flatness: ±1.0 dB (1 kHz–2.9 GHz) to ±3.0 dB (12.4–22.0 GHz)
• Multiple input protection options for continuous and pulsed signals
• Portable form factor with field-grade mechanical integrity
– Typical Applications
• RF/microwave signal detection and characterization
• Frequency and power measurement in EMC/EMI surveys
• In-field spectrum monitoring and interference identification
• Modulation analysis via AM/FM demodulation
– Compatibility & Integration
HP-IB remote control enables integration into automated measurement systems. Configurable reference input/output (BNC, 10 MHz) supports external frequency standards. LO and video outputs permit external processing chains.