Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Ando AQ6310C 400-1750nm Optical Spectrum Analyzer

SKU: AQ6310CCategories: Optical Spectrum Analyzers
Brand: Ando
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

Ando AQ6310C 400-1750nm Optical Spectrum Analyzer,Advanced optical spectrum analyzer covering wavelengths from 400 to 1750nm. Provides high resolution, dynamic range, and fast response time. Used for component testing, laser tuning, and system validation in telecom and photonics research.

Request CalibrationRequest Repair
Product Starting From:

$6,779.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote AQ6310C
Equipment info

Ando AQ6310C 400-1750nm Optical Spectrum Analyzer,The Ando AQ6310C is a high-performance optical spectrum analyzer offering spectral measurements across 400 to 1750 nm. It is tailored for testing a broad range of optical signals including laser sources, passive components, and broadband light sources. With high wavelength resolution, wide dynamic range, and fast sweep speeds, the unit allows for detailed spectrum characterization in R&D and manufacturing environments. The analyzer supports automated measurement functions and USB/GPIB interfaces for easy integration. It is widely used in fiber optic communications, photonics research, and production line testing. Its precise performance and versatile measurement capabilities make it indispensable for spectrum verification and troubleshooting tasks.

Aumictech – Ando AQ6310C Optical Spectrum Analyzer 400–1750 nm Specifications

Optical Performance

  • Wavelength range: 400 to 1750 nm

  • Span: 0.2 nm to full range

  • Wavelength accuracy: ±0.02 nm (typical in C-band), ±0.1 nm across full range

  • Wavelength resolution: 0.02 nm minimum

  • Wavelength repeatability: ±0.005 nm

  • Sampling resolution: 0.001 nm minimum

Level / Power Measurement

  • Sensitivity (typical):

    • −85 dBm (1000–1600 nm)

    • −70 dBm (400–1000 nm)

  • Maximum safe input power: +20 dBm

  • Power accuracy: ±0.3 dB (−20 dBm input at 1550 nm)

  • Linearity: ±0.05 dB (−50 to +10 dBm)

  • Flatness: ±0.2 dB across 400–1750 nm

  • Polarization dependence: ≤ ±0.05 dB

Dynamic Range & Stray Light

  • Dynamic range (typical):

    • Up to 78 dB (0.05 nm RBW, ±1 nm)

    • Up to 58 dB (0.02 nm RBW, ±0.2 nm)

  • Stray light suppression ratio: 78 dB typical

  • Level range: +20 to −85 dBm

Sweep & Speed

  • Sweep times (typical, 100 nm span):

    • FAST mode: ~0.5 s

    • NORMAL mode: ~2 s

    • HIGH SENS mode: 30–60 s

  • Sweep modes: single, repeat, and continuous

Fiber & Optical Interfaces

  • Input fiber types: Single-mode and multimode (9/125 µm, 50/62.5/125 µm)

  • Optical input connectors: FC, SC, ST (via interchangeable adapters)

  • Optical return loss: >30 dB typical

  • Calibration source: built-in wavelength reference

Interfaces & Control

  • Remote control: GP-IB (IEEE-488), RS-232C standard

  • Optional interface: Ethernet (for PC integration and automation)

  • Command compatibility: SCPI compliant

Display & Storage

  • Display: 9-inch color CRT (vector style)

  • Trace functions: multiple trace storage, Max/Min hold, subtraction

  • Data output: GP-IB/RS-232 to PC

  • Printer support: external GPIB printer compatible

Physical & Power

  • Dimensions: approx. 425 × 200 × 450 mm (W×H×D)

  • Weight: approx. 18–20 kg

  • Power supply: 100–240 VAC, 50/60 Hz, ~150 VA

  • Operating environment:

    • Performance guaranteed: +18 to +28 °C

    • Operating: +5 to +35 °C

    • Storage: −10 to +50 °C

    • Humidity: ≤80 %RH non-condensing

  • Warm-up time: ~1 hour