The Anritsu CMA 5302 is a modular Optical Time Domain Reflectometer (OTDR) with integrated chromatic dispersion measurement capability, designed for single-mode fiber characterization across extended distances. Operating at 1310 nm, 1550 nm, and 1625 nm, the CMA 5302 delivers 38 dB dynamic range with 0.001 dB loss resolution and ±0.0025% distance accuracy. The module integrates a power meter, light source, and OTDR function into a single instrument, enabling rapid fiber installation, maintenance, and fault location workflows.
Technical Specifications
• Wavelengths: 1310 nm ±20 nm, 1550 nm ±25 nm, 1625 nm ±15 nm
• Dynamic Range: 38 dB at all three wavelengths
• Pulsewidth: 5 ns to 20 µs (wavelength dependent)
• Distance Range: 5, 20, 50, 125, 250, 300 km
• Distance Resolution: 0.0001 km, 0.1 m, 1 ft, 0.0001 mi
• Distance Accuracy: ±0.0025% of distance measurement ± distance resolution ± index uncertainty
• Loss Resolution: 0.001 dB
• Data Points: Up to 256,000
• Spectral Width (RMS): <15 nm
• Linearity: 0.04 dB/dB
• Initial Reflective Deadzone: 4 m (typical)
• Initial Non-Reflective Deadzone: 9 m at 1310 nm, 8 m at 1550 nm, 9 m at 1625 nm (typical)
• Chromatic Dispersion Range: 1310 nm through 1625 nm (37 dB typical dynamic range)
• CD Measurement Method: Time of flight (FOTP-168)
• Power Meter Range: +20 dBm
• Light Source Output: -7 dBm for single-mode fiber
– Key Features
• Tri-wavelength OTDR with chromatic dispersion analysis
• Integrated power meter and light source
• Distance sampling: 0.125, 0.25, 0.5, 1, 2, 4, 8, 16 m (range dependent)
• Modular design for Anritsu CMA5000a mainframe (SBA, MBA, or LBA compatible)
• Connector adapters available: FC/UPC, SC/UPC, ST/UPC, FC/APC, SC/APC
– Typical Applications
• Single-mode fiber installation and acceptance testing
• Fault location and cable loss characterization
• Dispersion profile measurement over long-distance links
• Field maintenance and troubleshooting of optical networks
– Compatibility & Integration
The CMA 5302 operates as a module within the Anritsu CMA5000a platform. Mainframe bay configuration (Small, Medium, or Large) determines form factor and available concurrent measurements.