The Dranetz PP1/P is a portable power quality analyzer used for monitoring and troubleshooting electrical systems. It measures voltage, current, harmonics, and other power parameters to identify power quality issues.

Request CalibrationRequest Repair
Product Starting From:

$1,200.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote PP1/P
Equipment info

The Dranetz PP1/P is a versatile, portable power quality analyzer designed for comprehensive monitoring and analysis of electrical systems. Its modular TASKCard® architecture allows users to customize its functionality for specific applications, such as power quality, harmonics, energy, inrush current, and flicker analysis. This adaptability makes it suitable for a wide range of technical users, including engineers, system integrators, and laboratory personnel in the USA.

### Technical Specifications

**General:**
* **Manufacturer:** Dranetz BMI
* **Model:** PP1 / PP1/P
* **Instrument Type:** Portable Power Quality Analyzer
* **Architecture:** TASKCard®-driven with modular functionality
* **Display:** Large, easy-to-read LCD with electroluminescent backlighting
* **Setup:** Easy Start™ for automated configuration
* **Operation Modes:** Scope Mode®, Meter Mode, Data Recorder, Time Plots
* **Power Source:** 90-130 VAC or 180-250 VAC, 47-450 Hz, 100W max; 12 VDC 10A external input
* **Internal UPS:** Two-hour battery backup
* **Warm-up Period:** 15 minutes for optimal performance

**Measurement Capabilities (TASKCard Dependent):**
* **Power Quality:** Cycle-by-cycle monitoring of sags, swells, transients (voltage and current) per IEEE 1159. Classifies power quality disturbances to IEEE 1159 standard.
* **Harmonics:** Simultaneous monitoring of harmonics.
* **Energy:** Demand, energy, and harmonics analysis. Programmable demand and energy rate schedules for revenue calculations.
* **Inrush Current:** Records voltage and current inrush events cycle by cycle. Ideal for analyzing motor start-ups, transformer magnetization, and breaker operations.
* **Flicker:** Continuous monitoring of single or three-phase flicker parameters per IEC 868 and IEC 1000-4-15. Displays probability graphs, min/max reports, and subharmonics spectrum.
* **Parameters Measured (with TASKCard 8000):** V, I, W, VA, VAR, PF, Demand & Energy.
* **Waveform Capture:** Available with TASKCard PQPlus.

**Electrical:**
* **Input Channels:** 8 channels total: 4 fully differential voltage channels and 4 current channels.
* **Voltage Measurements:**
* Channels A, B, C: 10-600 Vrms max.
* Channel D: 1-60 Vrms max (low voltage range).
* Each channel input: +/- differential inputs from 60 to 600Vrms max.
* Accuracy: ±1% of reading ±0.05% of full scale for voltage measurements (with TASKCard PQPlus).
* Voltage Transients: 50-6000Vpk with a minimum duration of 1 microsecond (with TASKCard PQPlus). Accuracy: ±10% of reading ±1% of full scale.
* **Current Measurements:**
* Up to 3000 A depending on optional current probes (e.g., CT-10, CT-150, CT-300, CT-1000, CT-3000, LEMFLEX 3K).
* Accuracy: ±1% of reading ±0.05% of full scale (at fundamental, plus current probe accuracy).
* Current Transients: 1 to 300% of CT full-scale rating (except Chan D, 2-200%), 1 microsecond minimum duration (with TASKCard PQPlus). Accuracy: ±10% of reading ±1% of full scale plus probe accuracy.
* **Frequency:** Fundamental range 30 – 450 Hz. Accuracy: ±0.2% of reading.
* **Relay Contacts:** Four sets of relay contacts rated for 120 VAC at 1A max, 30 VDC at 1A max.
* **Digital Inputs:** Four channels, 12-48 VDC.

**Interfaces:**
* **Serial:** RS-232C DCE (DB-9 connector).
* **Parallel Port:** For PC connection.
* **Memory Card Interface:** Integral PCMCIA Type I (PC card) SRAM card slot for data storage (options for 512KB, 1MB, 2MB).
* **Relay Output:** Four sets of programmable relay contacts.

**Physical:**
* **Weight:** Approximately 21 lbs.
* **Operating Temperature:** 5 to 45 degrees Celsius (41 to 113° F).
* **Storage Temperature:** -20 to 55 degrees Celsius (-4 to 131° F).

**Compatibility:**
* **TASKCards:** Supports various TASKCards for expanded functionality, including PQPlus, 8000 (Energy/Harmonics), Inrush, and Flicker.
* **Software:** Supported by DRAN-VIEW PC analysis and report writing software. DRAN-LINK for PC interface via RS-232 or modem connection.
* **Current Probes:** Compatible with a range of Dranetz current probes (CT-10, CT-150, CT-300, CT-1000, CT-3000, ISO-1A, ISO-5, LEMFLEX 3K) and associated adapter cables.