The DynamicSignals/Kinetic Systems P300-343A is a 16-channel Form C relay output mezzanine card for VXIbus systems. It provides isolated SPDT relay contacts via optical isolators (LED/photo-transistor), enabling switching control in industrial automation and process control applications. The card mounts directly into Kinetic Systems V387 VXIbus modules, supporting up to four mezzanine cards for 32-channel configurable I/O. Each channel draws 5 mA to 15 mA and features programmable input filtering from 5 µs to over 1 second in 64 discrete steps. Contact closure represents logical “1.” The system supports multiple isolated input voltage versions—5 Vdc, 12 Vdc, 16 Vdc, 24 Vdc, 28 Vdc, 48 Vdc, and 120 Vac—with switching thresholds set at approximately half the rated input voltage. Integrated power-up self-test and software-initiated diagnostics provide Pass/Fail indication. Pattern recognition operates in 16-bit increments. Handshake logic is programmable with selectable external handshake support.
## Technical Specifications
• **Channels:** 16
• **Output Type:** Form C Relay (SPDT reed relays)
• **Input Current per Channel:** 5 mA to 15 mA
• **Input Isolation:** Optical isolator (LED/photo-transistor) with post-isolator filtering
• **Filter Time Constant:** 5 µs to over 1 second, 64 programmable steps
• **Supported Input Voltages:** 5 Vdc, 12 Vdc, 16 Vdc, 24 Vdc, 28 Vdc, 48 Vdc, 120 Vac
• **Switching Threshold:** ≈50% of rated input voltage
• **Logic Convention:** Contact closure (voltage present) = logical “1”
• **Form Factor:** Mezzanine card for VXIbus module insertion
## Key Features
• Optical isolation for each input channel
• Programmable input filtering in 64 discrete steps
• Automatic power-up self-test with software trigger capability
• 16-bit programmable pattern recognition
• Optional external handshake circuitry with programmable logical sense
• Configurable with up to four mezzanine cards per V387 module
## Typical Applications
• Industrial automation and control systems
• Process control switching operations
• VXI-based test and measurement systems
• Equipment requiring isolated relay actuation
## Compatibility & Integration
The P300-343A integrates with Kinetic Systems V387 VXIbus modules via standard mezzanine card insertion. Configuration management and trigger generation are accessible through VXIbus Configuration Register offsets.