The KGS Electronics SPC-6-750 is a solid-state frequency changer that converts standard AC input power into a stable 400 Hz sine wave output. Single-phase design with dual output voltage capability (115 VAC and 26 VAC) delivers up to 750 VA total power, making it ideal for avionic test benches, radar systems, compass calibration, and flight simulator power supplies. Built-in protection includes input overvoltage shutdown (>135 VAC), 15 A circuit breaker, output frequency monitoring, and audible overload warning.
## Technical Specifications
**Input**
• Voltage: 115 VAC ± 15 VAC
• Frequency: 50/60 Hz
• Phase: Single
• Protection: Overvoltage shutdown above 135 VAC; 15 A circuit breaker (power on/off switch)
**Output**
• Voltage: 115 VAC (100–125 VAC adjustable) or 26 VAC (22.6–28.2 VAC adjustable)
• Power: 750 VA at 115 VAC; 500 VA at 26 VAC; 750 VA total
• Frequency: 400 Hz (380–420 Hz adjustable)
• Waveform: Sine wave
• Amplitude Distortion: 2% typical
• Power Factor: 0.8–0.95
**Environmental & Physical**
• Operating Temperature: −40°C to +71°C
• Dimensions: 17″ W × 13″ D × 7″ H (19″ relay rack compatible)
• Weight: 32 lbs
• Cooling: Internal thermostatically controlled fan
## Key Features
• Dual-output configuration supports both 115 VAC and 26 VAC loads simultaneously
• 400 Hz sine wave output with ±20 Hz adjustment range maintains precision for frequency-sensitive equipment
• Overload capability: delivers 150% rated current for minimum 5 minutes
• Short-circuit withstand: maintains operation for minimum 1 minute under fault conditions
• Automatic shutdown when output frequency falls below 375 Hz or exceeds 425 Hz, or when output voltage exceeds 130 VAC
• Audible warning triggers at 130% rated load
• Low amplitude distortion (2% typical) ensures clean power delivery
## Typical Applications
• Avionic test benches requiring 400 Hz power standards
• Radar system power conditioning
• Compass calibration equipment
• Flight simulator power supplies
• Military and aerospace ground support equipment
## Compatibility & Integration
• Front panel: 5-way binding posts
• Rear panel: 6-32 terminal block connections
• Single-phase input and output architecture simplifies integration into existing lab and test environments