The TDK-Lambda GEN16-310 is a 4960 W programmable DC power supply delivering 0–16 VDC at 0–310 A for industrial, OEM, and laboratory applications. This 2U rack-mount unit combines low output ripple noise (0.01 Vrms, 1.4 Arms across 5 Hz to 1 MHz) with active power factor correction (0.99 typical) and 84% typical efficiency. It operates from three-phase AC input (208 VAC, 400 VAC, or 480 VAC models available) at 47–63 Hz and features CV/CC auto-crossover output configuration with adjustable overvoltage protection, undervoltage lockout, and current foldback. Up to four units connect in parallel with active current sharing for higher-power applications.
## Technical Specifications
• Output: 0–16 VDC, 0–310 A (4960 W rated)
• Input: 3-phase 170–265 VAC (208V), 342–460 VAC (400V), or 432–528 VAC (480V) at 47–63 Hz
• Voltage ripple: 0.01 Vrms; current ripple: 1.4 Arms (5 Hz to 1 MHz)
• Efficiency: 84% typical; power factor: 0.99 typical (active correction)
• Output ripple and noise specifications measured across 5 Hz to 1 MHz bandwidth
## Key Features
• CV/CC auto-crossover with adjustable OVP and UVL
• Parallel operation: four units with active current sharing
• Standard RS-232 and RS-485 interfaces; optional LAN (LXI), USB, GPIB
• Remote analog control (0–5 V or 0–10 V selectable via DIP switch)
• Multi-drop capability supporting up to 31 units over RS-485
• Front-panel encoders for voltage and current adjustment (fine/coarse selectable)
• Four-digit LED meters for voltage and current display
• Current foldback (can latch output off); safe re-start; last-setting memory
• Output on/off control; local/remote digital selection; front-panel lockout
## Typical Applications
Industrial power testing, OEM equipment integration, and laboratory bench work requiring stable, low-noise DC output with full remote programmability and protection.
## Compatibility & Integration
19″ rack mount (2U); 423 mm × 88 mm × 442.5 mm; 16 kg. LabWindows driver support. Meets IEC61010-1, CSA C22.2 No.61010-1, EN61010-1, UL61010-1, UL60950-1; CE/UKCA marked.