Lecroy DA1855 High-performance Differential Amplifier, 100MHz

SKU: DA1855Categories: Signal Conditioning Modules
Brand: Lecroy
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

The Lecroy DA1855 is a high-performance differential amplifier with a bandwidth of 100MHz. It is designed for amplifying differential signals in a variety of applications, including high-speed data acquisition, communications, and signal integrity testing.

Request CalibrationRequest Repair
Product Starting From:

$4,979.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote DA1855
Equipment info

The LeCroy DA1855 is a high-performance differential amplifier delivering DC to 100 MHz bandwidth for precision signal conditioning across oscilloscopes, digitizers, and spectrum analyzers. Selectable gains of 1× and 10× combined with a 10× input attenuator provide effective gains of 10, 1, or 0.1—with automatic display of combined effective gain accounting for probe, amplifier, and attenuator settings. An exceptional 100,000:1 (94 dB) CMRR and overdrive recovery enable accurate differential measurements in high-noise environments.

Technical Specifications

Bandwidth & Gain
• Bandwidth: DC to 100 MHz
• Selectable gain: 1× and 10×
• Input attenuator: 10× selectable attenuation
• Effective gain display: Automatic combined gain calculation
• Bandwidth limit filters: 100 kHz, 1 MHz, 10 MHz, 20 MHz, or full 100 MHz

Precision Voltage Generator (PVG)
• Output range: ±15.5 V (comparator mode); ±10 V (differential offset mode)
• Resolution: 100 µV / 5-1/2 digit
• DC accuracy: 0.05% + 500 µV (15°C to 45°C)
• PVG voltage accuracy: ±1% of reading ± 500 µV
• Temperature coefficient: <5 ppm/°C of full scale

Performance Characteristics
• CMRR: 100,000:1 (94 dB) at DC; ≥50,000:1 (94 dB) at 70 Hz and 100 kHz; ≥316:1 (50 dB) at 10 MHz
• Overdrive recovery: From 400 V input signal to <100 mV (÷100 probe) in 100 ns; to <1 mV (10× gain) in 100 ns
• Input noise (10× gain): <4 nV/√Hz broadband
• DC drift (10× gain): 50 µV/°C
• Rise time: <3.5 ns typical

Auto-Zero & Control
• Auto-zero: Adjusts DC balance on each gain change; sets output to zero when 0.0 V selected
• Control interface: Full control via ProBus from compatible Teledyne LeCroy oscilloscopes

– Key Features

• Selectable bandwidth limiting via three 3-pole low-pass filters
• Front-panel PVG control with rear-panel output connector for external use
• Differential offset accuracy (referred to input) down to 0.1% + 50 µV + PVG error at 10× gain with ÷1 attenuator

– Typical Applications

High-speed data acquisition, communications signal integrity testing, and precision differential measurements where common-mode rejection and rapid overdrive recovery are critical.

– Compatibility & Integration

Direct instrument control via ProBus interface from Teledyne LeCroy oscilloscopes. External PVG output available for standalone differential comparator or offset voltage applications.

MPN

DA1855

Frequency Range

DC to 100 MHz

Voltage / Current Range

±15.5 V (comparator mode); ±10 V (differential offset mode)