The LeCroy WavePro 960 is a 2 GHz digital oscilloscope built for signal analysis across engineering disciplines requiring high-fidelity waveform capture and detailed troubleshooting. With four analog input channels, configurable sampling up to 16 GS/s on repetitive signals, and optional memory expansion to 64 Mpts/channel, this instrument delivers the acquisition depth needed for single-shot transient events and extended signal characterization. Its SMART Memory system automatically optimizes the balance between memory depth and sample rate, eliminating manual configuration overhead.
The WavePro 960 combines 8-bit vertical resolution with Enhanced Resolution (ERES) up to 11 bits, DC accuracy of ±2.0% full scale, and rise time under 175 ps for precision analog measurements. Dual input impedance options—1 MΩ with 12 pF capacitance or 50 Ω—support both high-impedance probing and RF work. Input sensitivity spans 1 mV to 2 V/div on 1 MΩ channels and 1 mV to 1 V/div on 50 Ω, with fully variable gain control.
Technical Specifications
• Bandwidth: 2 GHz
• Channels: 4 analog inputs
• Maximum Sample Rate: 16 GS/s (repetitive), 8 GS/s per channel (3–4 channels), 4 GS/s per channel (standard)
• Acquisition Memory: 250 kpts/channel standard; 1 Mpts/channel standard; up to 64 Mpts/channel optional
• Vertical Resolution: 8 bits, up to 11 bits with Enhanced Resolution (ERES)
• Sensitivity: 1 mV–2 V/div (1 MΩ), 1 mV–1 V/div (50 Ω)
• DC Accuracy: ±2.0% full scale + 1.5% offset value @ gain > 10 mV
• Input Impedance: 1 MΩ || 12 pF or 50 Ω ± 1.5%
• Maximum Input Voltage: 5 Vrms (50 Ω), 100 Vmax (1 MΩ, peak AC ≤5 kHz + DC)
• Timebase: 500 ps/div to 1000 s/div (or 200 ps/div–1000 s/div)
• Rise Time: < 175 ps
• Clock Accuracy: ≤10 ppm
• Sampled Waveform Interval: Every 62.5 picoseconds
– Key Features
• SMART Triggers® with nine trigger types: Edge, Pulse Width, Runt, Timeout, Transition, Setup/Hold, Logic, Pattern, Serial
• Exclusion triggers to reject abnormal signals and focus on valid events
• Single-shot capture up to 64 Mpts for transient and one-time phenomena
• Bandwidth limiters at 20 MHz and 200 MHz
• Channel-to-channel isolation exceeding 250:1 at matched V/div settings
• External clock input to 500 MHz; external trigger range ±0.5 V (±2.5 V with Ext/5)
• Input coupling options: AC, DC, GND (1 MΩ); DC, GND (50 Ω)
– Typical Applications
• Complex signal debugging and validation in embedded systems
• High-speed protocol analysis and characterization
• Transient and anomalous event capture
• RF and analog circuit development
• Power integrity and signal quality assessment
– Compatibility & Integration
The oscilloscope accepts PP005 probes and supports both 1 MΩ and 50 Ω external trigger and clock inputs, enabling integration with automated test systems and lab instrumentation.