The Marconi IFR Aeroflex 56924/002 is a precision RF power sensor engineered for accurate power measurements from 10 MHz to 40 GHz. This field-replaceable sensor integrates with IFR 6960 Series and 6970 power meters, CPM 20 and CPM 46 counter power meters, and 6200 Series microwave test sets through automatic sensor recognition and scaling. The unit measures power levels from −70 dBm to −20 dBm with low VSWR and supplied linearity correction data for enhanced accuracy. Housed in a compact 88.5 mm × 33.5 mm form factor weighing 140 g, the sensor features a 2.92 mm coaxial connector and includes a Waveguide 22 to 2.92 mm coax transition with dual calibration tables for waveguide and coaxial measurements traceable to national standards.
Technical Specifications
• Frequency Range: 10 MHz to 40 GHz
• Power Measurement Range: −70 dBm to −20 dBm
• RF Connector: 2.92 mm male
• Calibration Factor: 0.01% resolution
• Dimensions: 88.5 mm length × 33.5 mm diameter
• Weight: 140 g
– Key Features
• Low VSWR for reduced measurement uncertainty
• Linearity correction data supplied with sensor
• Field-replaceable RF assembly minimizing maintenance downtime
• High overload capability extending operational lifetime
• Rugged construction suitable for bench and field deployment
• Compact, lightweight design requiring no additional mechanical support
• Precision connectors ensuring reliable connections
• Calibration table provided for accurate waveguide and coaxial measurements
– Typical Applications
RF power measurement across microwave frequencies, calibration verification, system acceptance testing, and field service measurements where accuracy and portability are required.
– Compatibility & Integration
The 56924/002 automatically integrates with IFR 6960B and 6970 power meters, CPM 20 and CPM 46 counter power meters, and 6200B series microwave test sets. Automatic sensor recognition circuits in compatible instruments select correct scaling upon connection. Includes Waveguide 22 to 2.92 mm coax transition and dual calibration tables as part of the 56924/002 configuration.