The Marconi IFR Aeroflex 6203 is a microwave test set that integrates signal generation, power measurement, frequency counting, and scalar network analysis into a single portable instrument. Operating from 10 MHz to 26.5 GHz, it delivers fast synthesized signal generation with 1 Hz resolution, capable of executing 400-point sweeps in under 200 ms. The instrument combines analog sweeper speed with synthesizer precision across Start/Stop, Center/Span, and CW sweep modes. Built-in power measurement, frequency counter, scalar analyzer, and real-time fault location with 0.1% accuracy make it suitable for laboratory and field characterization of microwave components and transmission line systems.
Technical Specifications
Frequency Range: 10 MHz to 26.5 GHz
Signal Generation
• Synthesized generator with 1 Hz resolution
• Output power: -20 dBm typical (10 MHz–10 GHz), -15 dBm (10–20 GHz), -10 dBm (20–26.5 GHz)
• Maximum output: +5 dBm; peak: +27 dBm
• Reverse input power rating: 100 mW maximum
• Step Attenuator Option (001): 70 dB or 90 dB attenuation; minimum leveled power -80 dBm or -100 dBm
Frequency Measurement
• Integral frequency counter
• CW mode accuracy: ±1 Hz ± frequency standard error
• Swept mode accuracy: ±100 Hz ± frequency standard error
Power Measurement
• Integral power meter with 2 m sensor cable (06950-081)
• Optional 6910 Series sensors: -30 dBm to +20 dBm
• Accuracy (including flatness at 0 dBm): ±1 dB, ±0.5 dB typical
• Linearity: <0.5 dB over guaranteed power range
Scalar Analysis
• Integral scalar analyzer with EEPROM-corrected 6230 and 6233 detectors
• 6230: 10 MHz to 20 GHz, N type connector
• 6233: 10 MHz to 26.5 GHz, MPC 3.5 mm connector
• AC detection: 80 dB; DC detection: 70 dB
• Modulation depth: Up to 40%
Fault Location
• Real-time return loss (VSWR) measurement against distance
• Accuracy: 0.1% of range up to 1 km
• Normal mode: <250 ms; Enhanced mode: <500 ms
Sweep Performance
• 401 points: <200 ms
• 1601 points: <800 ms
– Key Features
• Fast synthesized source combining analog sweep speed with frequency precision
• Dynamic calibrator and EEPROM correction for scalar measurements
• Portable design for both laboratory and field use
• Real-time transmission line fault identification
– Typical Applications
• Microwave component characterization
• Cable and waveguide fault location
• System validation and acceptance testing
– Compatibility & Integration
Power sensors from the 6910 Series integrate directly. Scalar detectors (6230 and 6233 series) support rapid field-portable measurements without external calibration references.